The early remodeling phases around titanium implants: a histomorphometric assessment of bone quality in a 3- and 6-month study in sheep.

نویسندگان

  • D Chappard
  • E Aguado
  • G Huré
  • F Grizon
  • M F Basle
چکیده

The purpose of this study was to evaluate the quality of the bone matrix around commercially pure titanium implants at 3 and 6 months postplacement in sheep. Implants were placed in the corticotrabecular areas of both femurs in 6 animals. Each animal received 4 Euroteknika implants in the right femur and 4 Nobel Biocare implants in the left femur. Bone blocks containing the implants were studied undecalcified after being embedded in methylmethacrylate. Sections were stained with toluidine blue and basic fuchsin. The amount of bone around the implants, the contact interface between the implant and bone, and the mineral apposition rates were measured. The fractional amount of woven bone could be quantified because of its high glycosaminoglycan content. No differences could be observed between the 2 types of implants. Total bone volume did not increase around both types of implants between 3 and 6 months, indicating that ankylosis was rapidly achieved. In contrast, in the area in contact with the implant, the bone-titanium interface drastically increased and the mineral apposition rate decreased. The fractional volume of woven bone around implants was considerably reduced after 6 months. Bone quality around implants was improved at 6 months (volume of woven bone near zero), and true osteonic structures were observed in close contact with titanium. The remodeling process appeared to improve bone quality and increase the bone-titanium interface around implants, while the net bone quantity necessary to immobilize implants was achieved rapidly and remained unchanged.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Osseointegration of Zirconia (Y-TZP) Dental Implants: A Histologic, Histomorphometric and Removal Torque Study in the Hip of Sheep

Objectives: The purpose of the present study was to demonstrate the biocompatibility and rigid osseointegration of a zirconia (Y-TZP) dental implant with acid-etched surface. Materials and methods: Eight zirconia (Y-TZP) implants (CeraRoot, Barcelona) were inserted in the hip of an adult sheep. The animal was sacrificed after 2 months. Four implants were used for histology and histomorphometric...

متن کامل

659-666 Ellingsen

Purpose: The purpose of the present study was to investigate whether a fluoride modification of the titanium surface would have an effect on bone response after implantation. Materials and Methods: Titanium-oxide–blasted titanium implants with and without fluoride modification were investigated in a rabbit tibia model. Quantitative analysis of surface roughness, biomechanical interlocking, and ...

متن کامل

Effect of Abutment Angulation and Material on Stress and Strain Distributions in Premaxillary Bone: A Three-Dimensional Finite Element Analysis

Background and Aim: Dental implants with angled abutments are often inserted in the anterior maxillary region due to the status of the residual ridge and aesthetic considerations. The purpose of this study was to assess stress and strain distributions in the premaxillary bone around dental implants by means of finite element analysis (FEA). Materials and Methods: Four three-dimensional (3D) fi...

متن کامل

Histomorphometric Analysis of Pure Titanium Implants with Porous Surface versus Rough Surface

The purpose of this study was to analyze the bone repair around commercially pure titanium implants with rough and porous surface, fabricated using powder metallurgy technique, after their insertion in tibiae of rabbits. Seven male rabbits were used. Each animal received 3 porous-surface implants in the left tibia and 3 rough-surface implants in the right tibia. The rabbits were sacrificed 4 we...

متن کامل

Use of titanium mesh for staged localized alveolar ridge augmentation: clinical and histologic-histomorphometric evaluation.

The use of titanium mesh for localized alveolar ridge augmentation was evaluated by clinical, radiographic, laboratory, and histologic-histomorphometric evaluation. Seventeen patients participated in this study. All patients required localized alveolar ridge augmentation before placement of dental implants. An equal mixture of autogenous bone graft and inorganic bovine mineral (Bio-Oss) was use...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 14 2  شماره 

صفحات  -

تاریخ انتشار 1999