Non-Invasive Hemoglobin Monitoring during Hemorrhage and Hypovolemic Shock

نویسنده

  • D J Saltzman
چکیده

Background: Serial blood draws for the assessment of a trauma patient’s hemoglobin (sHgb) and hematocrit (sHct) is standard practice. In the event of multiple casualties this process can be time consuming and lead to the inefficient use of valuable resources. A device that would allow for continuous real-time, non-invasive monitoring of hemoglobin and tissue perfusion would not only improve the utilization of scarce and valuable resources but would also improve triage efforts. Purpose: We developed a device utilizing the technology of Diffuse Optical Spectroscopy (DOS) to obtain non-invasive measurements of tissue hemoglobin concentration (THC) and oxygen consumption in an animal model of hypovolemic shock induced by successive blood withdrawals. Measured DOS results were compared against invasive systemic physiological measurements to demonstrate that DOS provides a reliable non-invasive measurement of tissue THC, and also quantifies various degrees of hemorrhage induced systemic hypovolemia and subsequent tissue perfusion decreases. Methods: Intubated New Zealand White rabbits (N=16) were hemorrhaged via a femoral arterial line every 10 minutes until a 20% blood loss (10-15 cc/kg) was achieved to attain hypovolemia. A DOS probe was placed on the inner thigh to measure muscle concentrations of oxygenated-Hgb (Hb-O2) and deoxygenatedHgb (Hb-R), during bloodletting. THC and tissue hemoglobin saturation (STO2) were calculated using oxygenated and deoxygenated hemoglobin concentrations. DOS-measured values were compared against traditional invasive measurements, systemic hemoglobin (sHgb), arterial oxygen saturation (SAO2), and venous oxygen saturation (SVO2) drawn from arterial and central venous blood. Systemic blood pressure (mAP), heart rate (HR) and SAO2, were monitored throughout the entire experiment. Results: DOS and traditional invasive measurements versus blood loss were closely correlated (R=0.98 and R=0.97, respectively) showing a decline in both. STO2 and Hb-O2 followed similar trends with hemorrhage whereas an increase in Hb-R was observed. Conclusion: DOS provides a potential platform for reliable non-invasive measurements of tissue oxygenated and deoxygenated hemoglobin and may accurately reflect the degree of systemic hypovolemia and compromised tissue perfusion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Broadband diffuse optical spectroscopy measurement of hemoglobin concentration during hypovolemia in rabbits.

Serial blood draws for the assessment of trauma patients' hemoglobin (sHgb) and hematocrit (sHct) is standard practice. A device that would allow for continuous real-time, non-invasive monitoring of hemoglobin and tissue perfusion would potentially improve recognition, monitoring and resuscitation of blood loss. We developed a device utilizing diffuse optical spectroscopy (DOS) technology that ...

متن کامل

Correlation of Ultrasonographic Measurement of Inferior Vena Cava Collapsibility Index with Central Venous Pressure in Diagnosis and Management of Neonatal Shock

Background: Neonatal intensive care unit (NICU)Conventionally, Central Venous Pressure (CVP) monitoring has beenused by intensivists to measure intravascular volume. However, it is an invasive procedure resulting in many complications. Non-invasive ultrasonographic measurement of inferior vena cava collapsibility index (IVC-CI) is a promising alternative. Therefore, this study wasconducte...

متن کامل

Near infrared spectroscopy (NIRS) of the thenar eminence in anesthesia and intensive care

Near infrared spectroscopy of the thenar eminence (NIRSth) is a noninvasive bedside method for assessing tissue oxygenation. The NIRS probe emits light with several wavelengths in the 700- to 850-nm interval and measures the reflected light mainly from a predefined depth. Complex physical models then allow the measurement of the relative concentrations of oxy and deoxyhemoglobin, and thus tissu...

متن کامل

Support Vector Machine Based Monitoring of Cardio-Cerebrovascular Reserve during Simulated Hemorrhage

Introduction: In the initial phase of hypovolemic shock, mean blood pressure (BP) is maintained by sympathetically mediated vasoconstriction rendering BP monitoring insensitive to detect blood loss early. Late detection can result in reduced tissue oxygenation and eventually cellular death. We hypothesized that a machine learning algorithm that interprets currently used and new hemodynamic para...

متن کامل

A non-inflatable anti-shock garment for obstetric hemorrhage.

OBJECTIVES Maternal death from hemorrhage in low resource settings is frequently due to long delays in transportation to referral centers and/or in obtaining blood and surgical interventions. This case series was designed to demonstrate the feasibility, efficacy and safety of the non-inflatable anti-shock garment (NI-ASG) for resuscitation and hemostasis in the initial management of obstetric h...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004