Validation testing of ANSI/IEEE n42.49 standard requirements for personal emergency radiation detectors.

نویسندگان

  • L Pibida
  • R Minniti
  • M O'Brien
چکیده

Various radiation detectors including electronic personal emergency radiation detectors (PERDs), radiochromic film cards and thermoluminescent dosimeters (TLDs) were used to validate a subset of the radiological test requirements listed in the American National Standards Institute/The Institute of Electrical and Electronic Engineers (ANSI/IEEE) N42.49 standard. The subset of tests included the following: comparing the readout of the detectors with the value given at the National Institute of Standards and Technology (NIST); testing of the alarm settings (when applicable) in air-kerma (or exposure) and air-kerma rate (or exposure rate) mode; and investigating the effect of testing the detectors mounted on a phantom and free in air. The purpose of this work was not to test the performance of the sample of detectors used. Instead, the detectors were used to validate the requirements of the written standard being developed. For this purpose, the performance and response of these instruments were recorded when placed in (137)Cs, and x-ray beams at different air-kerma rates and test conditions. The measurements described in this report were performed at the NIST x-ray and gamma-ray radiation calibration facilities. The data in this report provide a benchmark in support of the development of the ANSI/IEEE N42.49 standard.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Proficiency Testing for The Calibration of Radiation Measurement Instrument with Photon Radiation

Radiation monitoring and inspecting instruments are important tools for the measurement of radiation dose rate or radioactivity. Now in Taiwan, there are five laboratories (processors) capable of providing calibrations for radiation monitoring and inspecting instruments. All these five laboratories have been accredited by the Chinese National Laboratory Accreditation (CNLA). In the past, there ...

متن کامل

Establishment of ANSI N13.11 X-ray radiation fields for personal dosimetry performance test by computation and experiment.

This paper describes establishment by computational and experimental methods of the American National Standard Institute (ANSI) N13.11 X-ray radiation fields by the Korea Atomic Energy Research Institute (KAERI). These fields were used in the standard irradiations of various personal dosimeters for the personal dosimetry performance test program performed by the Ministry of Science and Technolo...

متن کامل

Software Testdokumentation nach den IEEE und ISO Standards

Test documentation is needed not only to assess the extent and quality of a test but also to assess the productivity of testers and to tie the test to the software architecture. Decision makers and auditors need test documentation to decide whether to release a version or not. Maintainers need test documentation to see how changes can be tested. Testers need test documents to help them identify...

متن کامل

Personal Dosimetry Performance Testing in the United States

The basis for personal dosimetry performance testing in the United States is ANSI/HPS N13.11. Now in it's fourth edition, this standard has been in place since 1983. Testing under this standard is administered by the National Voluntary Laboratory Accreditation Program (NVLAP), and accreditation of dosimetry processors under this program is required by U.S. Nuclear Regulatory Commission (NRC) re...

متن کامل

Performance Characteristics of a Third-generation Spectroscopic Vehicle Portal Monitor based on High Purity Germanium Detectors

The general need for improved detection performance and reduced decision time for portal monitors, freight container scanners, and mobile search systems is being achieved with systems utilizing High-Purity Germanium (HPGe) detectors. Highly specialized software analyzes the spectroscopic data to produce accurate results in live time. To meet the need, a new generation monitor has been developed...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Health physics

دوره 98 4  شماره 

صفحات  -

تاریخ انتشار 2010