Software-assisted dosimetry in peptide receptor radionuclide therapy with 177Lutetium-DOTATATE for various imaging scenarios

نویسندگان

  • Dennis Kupitz
  • Christoph Wetz
  • Heiko Wissel
  • Florian Wedel
  • Ivayla Apostolova
  • Thekla Wallbaum
  • Jens Ricke
  • Holger Amthauer
  • Oliver S Grosser
چکیده

In peptide receptor radionuclide therapy (PRRT) of patients with neuroendocrine neoplasias (NENs), intratherapeutic dosimetry is mandatory for organs at risk (e.g. kidneys) and tumours. We evaluated commercial dosimetry software (Dosimetry Toolkit) using varying imaging scenarios, based on planar and/or tomographic data, regarding the differences in calculated organ/tumour doses and the use for clinical routines. A total of 16 consecutive patients with NENs treated by PRRT with 177Lu-DOTATATE were retrospectively analysed. Single-photon emission computed tomography (SPECT)/low-dose computed tomography (CT) of the thorax and abdomen and whole body (WB) scintigraphy were acquired up to 7 days p.i. (at a maximum of five imaging time points). Different dosimetric scenarios were evaluated: (1) a multi-SPECT-CT scenario using SPECT/CT only; (2) a planar scenario using WB scintigraphy only; and (3) a hybrid scenario using WB scintigraphy in combination with a single SPECT/low-dose CT. Absorbed doses for the kidneys, liver, spleen, lungs, bladder wall and tumours were calculated and compared for the three different scenarios. The mean absorbed dose for the kidneys estimated by the multi-SPECT-CT, the planar and the hybrid scenario was 0.5 ± 0.2 Sv GBq-1, 0.8 ± 0.4 Sv GBq-1 and 0.6 ± 0.3 Sv GBq-1, respectively. The absorbed dose for the residual organs was estimated higher by the planar scenario compared to the multi-SPECT-CT or hybrid scenario. The mean absorbed tumour doses were 2.6 ± 1.5 Gy GBq-1 for the multi-SPECT-CT, 3.1 ± 2.2 Gy GBq-1 for the hybrid scenario and 5.3 ± 6.3 Gy GBq-1 for the planar scenario. SPECT-based dosimetry methods determined significantly lower kidney doses than the WB scintigraphy-based method. Dosimetry based completely on SPECT data is time-consuming and tedious. Approaches combining SPECT/CT and WB scintigraphy have the potential to ensure compromise between accuracy and user-friendliness.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The comparison of serial SPECT-CT imaging to estimate absorbed dose to the organ at risk from peptide receptor radionuclide therapy dosimetry

Introduction: In Peptide Receptor Radionuclide Therapy (PRRT), the administration of radionuclide such as Lu-177 label with a pharmaceutical agent useful to destroy the lesion. The amount of Lu-177 radioactivity administered to the patients is still not standardize and generally not more than 7.4 GBq per session due to the patient’s safety issues. The first cycle of Lu-177 is a...

متن کامل

Pharmacokinetic digital phantoms for accuracy assessment of image-based dosimetry in (177)Lu-DOTATATE peptide receptor radionuclide therapy.

Patient-specific image-based dosimetry is considered to be a useful tool to limit toxicity associated with peptide receptor radionuclide therapy (PRRT). To facilitate the establishment and reliability of absorbed-dose response relationships, it is essential to assess the accuracy of dosimetry in clinically realistic scenarios. To this end, we developed pharmacokinetic digital phantoms correspon...

متن کامل

Demonstration of focal physiologic in-vivo somatostatin receptor expression in the caput epididymis of the testes on 68Ga-DOTANOC PET/CT and 177Lu-DOTATATE post-therapy whole body scintigraphy

We present the case of a 60-year-old man with metastatic neuroendocrine tumor of the ileum following ileal resection, being evaluated for 177Lu-based peptide receptor radionuclide therapy. 68Ga-DOTANOC PET/CT showed focal increased tracer uptake in the scrotal region without any morphologic changes on the corresponding CT images. Similar increased tracer uptake was seen on...

متن کامل

Lutetium-177 DOTATATE Production with an Automated Radiopharmaceutical Synthesis System

Objective(s): Peptide Receptor Radionuclide Therapy (PRRT) with yttrium-90 (90Y) and lutetium-177 (177Lu)-labelled SST analogues are now therapy option for patients who have failed to respond to conventional medical therapy. In-house production with automated PRRT synthesis systems have clear advantages over manual methods resulting in increasing use in hospital-based radiopharmacies. We report...

متن کامل

Uncertainty propagation for SPECT/CT-based renal dosimetry in (177)Lu peptide receptor radionuclide therapy.

A computer model of a patient-specific clinical (177)Lu-DOTATATE therapy dosimetry system is constructed and used for investigating the variability of renal absorbed dose and biologically effective dose (BED) estimates. As patient models, three anthropomorphic computer phantoms coupled to a pharmacokinetic model of (177)Lu-DOTATATE are used. Aspects included in the dosimetry-process model are t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017