Heartbeat-induced axial motion artifacts in optical coherence tomography measurements of the retina.
نویسندگان
چکیده
PURPOSE To investigate the cause of axial eye motion artifacts that occur in optical coherence tomography (OCT) imaging of the retina. Understanding the cause of these motions can lead to improved OCT image quality and therefore better diagnoses. METHODS Twenty-seven measurements were performed on 5 subjects. Spectral domain OCT images at the macula were collected over periods up to 30 seconds. The axial shift of every average A-scan was calculated with respect to the previous average A-scan by calculating the cross-correlation. The frequency spectrum of the calculated shifts versus time was determined. The heart rate was determined from blood pressure measurements at the finger using an optical blood pressure detector. The fundamental frequency and higher order harmonics of the axial OCT shift were compared with the frequency spectrum of blood pressure data. In addition, simultaneous registration of the movement of the cornea and the retina was performed with a dual reference arm OCT setup, and movements of the head were also analyzed. RESULTS A correlation of 0.90 was found between the fundamental frequency in the axial OCT shift and the heart rate. Cornea and retina move simultaneously in the axial direction. The entire head moves with the same amplitude as the retina. CONCLUSIONS Axial motion artifacts during OCT volume scanning of the retina are caused by movements of the whole head induced by the heartbeat.
منابع مشابه
Segmentation guided registration of wide field-of-view retinal optical coherence tomography volumes.
Patient motion artifacts are often visible in densely sampled or large wide field-of-view (FOV) retinal optical coherence tomography (OCT) volumes. A popular strategy for reducing motion artifacts is to capture two orthogonally oriented volumetric scans. However, due to larger volume sizes, longer acquisition times, and corresponding larger motion artifacts, the registration of wide FOV scans r...
متن کاملImage Artifacts in Optical Coherence Tomography Angiography.
PURPOSE To describe image artifacts of optical coherence tomography (OCT) angiography and their underlying causative mechanisms. To establish a common vocabulary for the artifacts observed. METHODS The methods by which OCT angiography images are acquired, generated, and displayed are reviewed as are the mechanisms by which each or all of these methods can produce extraneous image information....
متن کاملImpact of motion-associated noise on intrinsic optical signal imaging in humans with optical coherence tomography.
A growing body of evidence suggests that phototransduction can be studied in the human eye in vivo by imaging of fast intrinsic optical signals (IOS). There is consensus concerning the limiting influence of motion-associated imaging noise on the reproducibility of IOS-measurements, especially in those employing spectral-domain optical coherence tomography (SD-OCT). However, no study to date has...
متن کاملClinical assessment of mirror artifacts in spectral-domain optical coherence tomography.
PURPOSE. To investigate the characteristics of a spectral-domain optical coherence tomography (SD-OCT) image phenomenon known as the mirror artifact, calculate its prevalence, analyze potential risk factors, measure severity, and correlate it to spherical equivalent and central visual acuity (VA). METHODS. OCT macular cube 512 x 128 scans taken between January 2008 and February 2009 at the New ...
متن کاملCorrecting Motion Artifacts in Retinal Spectral Domain Optical Coherence Tomography via Image Registration
Spectral domain optical coherence tomography (SD-OCT) is an important tool for the diagnosis of various retinal diseases. The measurements available from SD-OCT volumes can be used to detect structural changes in glaucoma patients before the resulting vision loss becomes noticeable. Eye movement during the imaging process corrupts the data, making measurements unreliable. We propose a method to...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 52 6 شماره
صفحات -
تاریخ انتشار 2011