Oxygen saturation, red blood cell tissue fraction and speed resolved perfusion - A new optical method for microcirculatory assessment.

نویسندگان

  • Hanna Jonasson
  • Ingemar Fredriksson
  • Anders Pettersson
  • Marcus Larsson
  • Tomas Strömberg
چکیده

We have developed a new fiber-optic system that combines diffuse reflectance spectroscopy (DRS) and laser Doppler Flowmetry (LDF) for a multi-modal assessment of the microcirculation. Quantitative data is achieved with an inverse Monte Carlo algorithm based on an individually adaptive skin model. The output parameters are calculated from the model and given in absolute units: hemoglobin oxygen saturation (%), red blood cell (RBC) tissue fraction (%), and the speed resolved RBC perfusion separated into three speed regions; 0-1mm/s, 1-10mm/s and above 10mm/s (% mm/s). The aim was to explore microcirculatory parameters using the new optical method, integrating DRS and LDF in a joint skin model, during local heating of the dorsal foot and venous and arterial occlusion of the forearm in 23 healthy subjects (age 20-28years). There were differences in the three speed regions in regard to blood flow changes due to local heating, where perfusion for high speeds increased the most. There was also a high correlation between changes in oxygenation and changes in perfusion for higher speeds. Oxygen saturation at baseline was 44% on foot, increasing to 83% at plateau after heating. The larger increase in perfusion for higher speeds than for lower speeds together with the oxygenation increase during thermal provocation, shows a local thermoregulatory blood flow in presumably arteriolar dermal vessels. In conclusion, there are improved possibilities to assess microcirculation using integrated DRS and LDF in a joint skin model by enabling both oxygenation and speed resolved blood flow assessment simultaneously and in the same skin site. Output parameters in absolute units may also yield new insights about the microcirculatory system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Model-based quantitative assessment of skin microcirculatory blood flow and oxygen saturation

The microcirculation, involving the smallest vessels in the body, is where the oxygen transport to all tissue occurs. Evaluating microcirculatory parameters is, therefore, important and involves the quantification of oxygen content of red blood cells (RBCs), the amount of RBCs and their speed. Diffuse reflectance spectroscopy (DRS) can be used to estimate blood oxygen saturation and fraction of...

متن کامل

Evaluation of a pointwise microcirculation assessment method using liquid and multilayered tissue simulating phantoms.

A fiber-optic probe-based instrument, designed for assessment of parameters related to microcirculation, red blood cell tissue fraction (fRBC), oxygen saturation (SO2), and speed resolved perfusion, has been evaluated using state-of-the-art tissue phantoms. The probe integrates diffuse reflectance spectroscopy (DRS) at two source-detector separations and laser Doppler flowmetry, using an invers...

متن کامل

Optical Monitoring of Cerebral Microcirculation

The cerebral microcirculation consists of a complex network of small blood vessels that support nerve cells with oxygen and nutrition. The blood flow and oxygen delivery in the microcirculatory blood vessels are regulated through mechanisms which may be influenced or impaired by disease or brain damage resulting from conditions such as brain tumors, traumatic brain injury or subarachnoid hemorr...

متن کامل

Redistribution of intestinal microcirculatory oxygenation during acute hemodilution in pigs.

Acute normovolemic hemodilution (ANH) compromizes intestinal microcirculatory oxygenation; however, the underlying mechanisms are incompletely understood. We hypothesized that contributors herein include redistribution of oxygen away from the intestines and shunting of oxygen within the intestines. The latter may be due to the impaired ability of erythrocytes to off-load oxygen within the micro...

متن کامل

First experience with a novel luminescence-based optical sensor for measurement of oxygenation in tumors

Background. The purpose of this preliminary study was to evaluate a novel luminescence-based fiber-optic sensor (OxyLite system) for the measurement of partial pressure of oxygen (pO2) in tumors and for the detection of changes in pO2 as a function of time. The new method was used simultaneously with the laser Doppler flowmetry method for the measurement of relative tissue perfusion. Materials ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Microvascular research

دوره 102  شماره 

صفحات  -

تاریخ انتشار 2015