Test-Retest and Interreader Reproducibility of Semiautomated Atlas-Based Analysis of Diffusion Tensor Imaging Data in Acute Cervical Spine Trauma in Adult Patients.
نویسندگان
چکیده
BACKGROUND AND PURPOSE DTI is a tool for microstructural spinal cord injury evaluation. This study evaluated the reproducibility of a semiautomated segmentation algorithm of spinal cord DTI. MATERIALS AND METHODS Forty-two consecutive patients undergoing acute trauma cervical spine MR imaging underwent 2 axial DTI scans in addition to their clinical scan. The datasets were put through a semiautomated probabilistic segmentation algorithm that selected white matter, gray matter, and 24 individual white matter tracts. Regional and white matter tract volume, fractional anisotropy, and mean diffusivity values were calculated. Two readers performed the nonautomated steps to evaluate interreader reproducibility. The coefficient of variation and intraclass correlation coefficient were used to assess test-retest and interreader reproducibility. RESULTS Of 42 patients, 30 had useable data. Test-retest reproducibility of fractional anisotropy was high for white matter as a whole (coefficient of variation, 3.8%; intraclass correlation coefficient, 0.93). Test-retest coefficient-of-variation ranged from 8.0%-18.2% and intraclass correlation coefficients from 0.47-0.80 across individual white matter tracts. Mean diffusivity metrics also had high test-retest reproducibility (white matter: coefficient-of-variation, 5.6%; intraclass correlation coefficient, 0.86) with coefficients of variation from 11.6%-18.3% and intraclass correlation coefficients from 0.57-0.74 across individual tracts, with better agreement for larger tracts. The coefficients of variation of fractional anisotropy and mean diffusivity both had significant negative relationships with white matter volume (26%-27% decrease for each doubling of white matter volume, P < .01). CONCLUSIONS DTI spinal cord segmentation is reproducible in the setting of acute spine trauma, specifically for larger white matter tracts and total white or gray matter.
منابع مشابه
Evaluation of Reproducibility of Diffusion Tensor Imaging in the Brachial Plexus at 3.0 T.
OBJECTIVE The aim of this study was to evaluate the reproducibility of 3 T magnetic resonance imaging diffusion tensor imaging (DTI) of the brachial plexus in healthy subjects. METHODS Ten healthy volunteers were included, and morphological and DTI sequences of the nerve roots of the brachial plexus from C5 to T1 of both sides were repeatedly acquired on a 3 T magnetic resonance system (MAGNE...
متن کاملMultisite longitudinal reliability of tract-based spatial statistics in diffusion tensor imaging of healthy elderly subjects
Large-scale longitudinal neuroimaging studies with diffusion imaging techniques are necessary to test and validate models of white matter neurophysiological processes that change in time, both in healthy and diseased brains. The predictive power of such longitudinal models will always be limited by the reproducibility of repeated measures acquired during different sessions. At present, there is...
متن کاملTest-Retest Reliability of Diffusion Tensor Imaging in Huntington’s Disease
Diffusion tensor imaging (DTI) has shown microstructural abnormalities in patients with Huntington's Disease (HD) and work is underway to characterise how these abnormalities change with disease progression. Using methods that will be applied in longitudinal research, we sought to establish the reliability of DTI in early HD patients and controls. Test-retest reliability, quantified using the i...
متن کاملMRI findings in patients with blunt cervical trauma having a normal level of consciousness and normal CT reports
Objective: This study investigates the possible magnetic resonance imaging (MRI) findings in patients with cervical trauma having a normal level of consciousness and normal CT reports. These patients have tenderness or an uncomfortable feeling in the traumatized area as well.Methods: In this cross-sectional anterograde study, cases were selected among patients referred to the emergency de...
متن کاملWithin Subject Averaging of Diffusion Tensor Mri Data Sets: a Test-retest Reproducibility Evaluation
INTRODUCTION The accuracy and precision of a Diffusion tensor imaging (DTI) acquisition of in-vivo human brains depends on both the acquisition protocol [1] and post-processing used for data analysis. In many cases multiple acquisitions from the same session are averaged to increase signal-to-noise ratio and reduce sensitivity to motion during the acquisition. The complexity of DTI datasets all...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 38 10 شماره
صفحات -
تاریخ انتشار 2017