Descemet Membrane Detachment in Femtosecond Laser-Assisted Cataract Surgery.

نویسندگان

  • Ricardo M Nosé
  • Maria Daniela Rivera-Monge
  • Adriana S Forseto
  • Walton Nosé
چکیده

PURPOSE To report a case series of 4 patients with Descemet membrane detachment (DMD) after undergoing femtosecond laser-assisted cataract surgery incisions. METHODS Case report. RESULTS DMD was noted at the secondary incision (n = 2) or at the main incision (n = 2). All the secondary incision and 1 main incision DMD were resolved with intraoperative maneuvers. Delay in recognizing DMD intraoperatively at the principal incision in 1 case led to inadvertent aspiration of a part of it and persistent postoperative corneal edema. This complication was handled with Descemet membrane endothelial keratoplasty 1 month after initial surgery. CONCLUSIONS DMD can occur after femtosecond laser-assisted cataract surgery, although it is a rare complication as it is in traditional phacoemulsification. The surgeon must be prepared to recognize it, manage it intraoperatively, and treat it postoperatively to reduce the risk of permanent damage to the eye.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Descemet membrane detachment in femtosecond laser-assisted cataract surgery: a case report

BACKGROUND Femtosecond laser-assisted cataract surgery (FLACS) has grown in popularity among ophthalmologists as a novel technique. However, descemet membrane detachment (DMD) began to be found as the complication after FLACS. We report a case of serious DMD following FLACS due to the inappropriate incision design. CASE PRESENTATION An 85-year-old man with apparent cornea arcus senilis underw...

متن کامل

Managing Descemet Detachment in Femtosecond Laser-Assisted Cataract Surgery: The Isolate-and-Release Technique.

To the Editor: Descemet detachment in cataract surgery can compromise visual results and implicate the need for more surgical procedures.1 Since 2009, when femtosecond laserassisted cataract surgery (FLACS) was first introduced, only one case of Descemet detachment has been reported in a study assessing intraoperative complication rates, and it is not clear whether the detachment was caused by ...

متن کامل

Comparison of morphologic features of clear corneal incisions created with a femtosecond laser or a keratome.

PURPOSE To compare the morphology of clear corneal incisions (CCIs) created with a femtosecond laser (Catalys) or a keratome (2.65 mm steel) during phacoemulsification using anterior segment optical coherence tomography (AS-OCT) and analyze the intended versus the achieved morphologic characteristics of femtosecond laser-generated CCIs. SETTING Northwestern University Feinberg School of Medic...

متن کامل

Femtosecond Laser Refractive Surgery after Descemet Stripping-Automated Endothelial Keratoplasty

Purpose. To report the use of femtosecond laser-assisted in situ keratomileusis (LASIK) in the treatment of hyperopia subsequent to Descemet stripping-automated endothelial keratoplasty (DSAEK). Methods. Interventional case report. Results. A 66-year-old woman with Fuchs endothelial dystrophy developed bullous keratopathy after cataract surgery in her right eye. She underwent DSAEK with a signi...

متن کامل

Outcomes of air descemetopexy for Descemet membrane detachment after cataract surgery.

PURPOSE To analyze the outcomes of post-cataract surgery descemetopexy for Descemet membrane detachment using intracameral air injection. SETTING Cornea Department, LV Prasad Eye Institute, Hyderabad, India. DESIGN Interventional case series. METHODS The clinical data of patients who had descemetopexy from August 2010 to February 2011 for Descemet membrane detachment after cataract surger...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cornea

دوره 35 4  شماره 

صفحات  -

تاریخ انتشار 2016