Aptamer-based optical biosensor for rapid and sensitive detection of 17β-estradiol in water samples.
نویسندگان
چکیده
Required routine monitoring of endocrine disrupting compounds (EDCs) in water samples, as posed by EPA Unregulated Contaminant Regulation (UCMR3), demands for cost-effective, reliable and sensitive EDC detection methods. This study reports a reusable evanescent wave aptamer-based biosensor for rapid, sensitive and highly selective detection of 17β-estradiol, an EDC that is frequently detected in environmental water samples. In this system, the capture molecular, β-estradiol 6-(O-carboxy-methyl)oxime-BSA, was covalently immobilized onto the optical fiber sensor surface. With an indirect competitive detection mode, samples containing different concentrations of 17β-estradiol were premixed with a given concentration of fluorescence-labeled DNA aptamer, which highly specifically binds to 17β-estradiol. Then, the sample mixture is pumped to the sensor surface, and a higher concentration of 17β-estradiol leads to less fluorescence-labeled DNA aptamer bound to the sensor surface and thus to lower fluorescence signal. The dose-response curve of 17β-estradiol was established and a detection limit was determined as 2.1 nM (0.6 ng mL(-1)). The high specificity and selectivity of the sensor were demonstrated by evaluating its response to a number of potentially interfering EDCs. Potential interference of real environmental sample matrix was assessed by spiked samples in several tertiary wastewater effluents. The sensor can be regenerated with a 0.5% SDS solution (pH 1.9) over tens of times without significant deterioration of the sensor performance. This portable sensor system can be potentially applied for on-site real-time inexpensive and easy-to-use monitoring of 17β-estradiol in environmental samples such as effluents or water bodies.
منابع مشابه
An Aptamer-based Biosensor for Troponin I Detection in Diagnosis of Myocardial Infarction
Background: Acute myocardial infarction (MI) accounts for one third of deaths. Cardiac troponin I (TnI) is a reliable biomarker of cardiac muscle tissue injury and is employed in the early diagnosis of MI.Objectives: In this study, a molecular method is introduced to early diagnosis of MI by rapid detection of TnI.Materials and Methods: The detection method was based on electrochemical aptasens...
متن کاملLabel-free aptamer-based electrochemical impedance biosensor for 17β-estradiol.
A novel aptamer-based label-free electrochemical impedance spectroscopy biosensor for 17β-estradiol has been fabricated. The aptamers were firstly immobilized on the gold electrode through Au-S interaction; the aptamer probe was then bound with the addition of 17β-estradiol to form the estradiol/aptamer complex on the electrode surface. This leads to a significantly larger interfacial electron ...
متن کاملPoint-of-care detection of Escherichia coli O157:H7 in water using AuNPs-based aptasensor
Objective(s): Access to safe drinking and irrigation water has always been one of the major human concerns worldwide. Thus, rapid, sensitive, and inexpensive approaches for pathogenic bacteria detection, such as Escherichia coli O157:H7 (EHEC) that can induce important infectious diseases, are highly on demand. Materials and Methods: In ...
متن کاملFabrication of a Voltammetric Biosensor in Combination with Enzyme-linked Immunosorbent Assay to Detect Aflatoxin M1 in Milks
Background and Objectives: Aflatoxin M1 is one the most important mycotoxin contaminants of milks. Various methods have been described to detect aflatoxins in milks, including chromatography, enzyme-linked immunosorbent assay and colorimetry. Regarding high sensitivity of electrochemical sensor based methods, the aim of the present study was to fabricate an accurate sensitive voltametric biosen...
متن کاملA colorimetric aptasensor for selective detection of oxytetracycline in milk, using gold nanoparticles and oxytetracline-short aptamer
Objective (s): In light of misuse of antibiotics in animal husbandry and their side effects on human health, there is an argent need to develop simple and rapid methods for determining the quantification of antibiotics in biological systems. Materials and Methods: In this work a facile and ultrasensitive colorimetric aptasensor was reported for detection of oxytetracycline (OTC) in water and mi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Environmental science & technology
دوره 46 6 شماره
صفحات -
تاریخ انتشار 2012