Plan quality and delivery time comparisons between volumetric modulated arc therapy and intensity modulated radiation therapy for scalp angiosarcoma: A planning study
نویسندگان
چکیده
INTRODUCTION Due to its spherical surface, scalp angiosarcoma requires careful consideration for radiation therapy planning and dose delivery. Herein, we investigated whether volumetric modulated arc therapy (VMAT) is superior to intensity modulated radiation therapy (IMRT) in terms of the plan quality and delivery time. METHODS Three different coplanar treatment plans were created for four patients, comprising a two-arc VMAT plan as well as 5-field and 9-field IMRT plans with 6 MV beams. The X-ray Voxel Monte Carlo algorithm was employed for dose calculation. A radiation therapy dose of 60 Gy was prescribed to the planning target volume (PTV) in 30 fractions. The homogeneity indexes (HIs) and conformity indexes (CIs) of the PTV, organs at risk (OARs) doses and delivery times were calculated and compared. RESULTS For the VMAT, 5-field and 9-field IMRT plans, the mean HIs were 0.14, 0.16 and 0.15; CIs100% were 0.63, 0.61 and 0.64; CIs98% were 0.72, 0.66 and 0.70 and CIs95% were 0.74, 0.67 and 0.71 respectively. All mean dose parameters of the VMAT and 9-field IMRT plans for the brain were equal to or lower than those of the 5-field IMRT plan. For the 5-field IMRT plan, the dose constraints for the left lens were not satisfied in two patients. The mean delivery times were 3.3, 11.1 and 14.7 min for the VMAT, 5-field and 9-field IMRT plans respectively. CONCLUSION The VMAT plan quality is comparable to that of 9-field IMRT, with a reduced delivery time. Therefore, VMAT represents a valuable, sophisticated irradiation technique for treating scalp angiosarcoma.
منابع مشابه
Dosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol
Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...
متن کاملThe evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy
Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...
متن کاملClustering of nasopharyngeal carcinoma intensity modulated radiation therapy plans based on k-means algorithm and geometrical features
Background: The design of intensity modulated radiation therapy (IMRT) plans is difficult and time-consuming. The retrieval of similar IMRT plans from the IMRT plan dataset can effectively improve the quality and efficiency of IMRT plans and automate the design of IMRT planning. However, the large IMRT plans datasets will bring inefficient retrieval result. Materials and Methods: An intensity-m...
متن کاملPerformance evaluation of gated volumetric modulated arc therapy
Background: Aim of this study is to evaluate the accuracy of the gated volumetric modulated arc therapy (VMAT/RapidArc) using 2D planar dosimetry, DynaLog files and COMPASS 3D dosimetry system. Materials and Methods: Pre-treatment quality assurance of 10 gated VMAT plans was verified using 2D array and COMPASS 3D dosimetry system. Advantage of COMPASS over 2D planar is that it provides the clin...
متن کاملThe Quality Control of Intensity Modulated Radiation Therapy (IMRT) for ONCOR Siemens Linear Accelerators Using Film Dosimetry
Introduction Intensity Modulated Radiation Therapy (IMRT) has made a significant progress in radiation therapy centers in recent years. In this method, each radiation beam is divided into many subfields that create a field with a modulated intensity. Considering the complexity of this method, the quality control for IMRT is a topic of interest for researchers. This article is about the various ...
متن کامل