Rod- and cone-isolated flicker electroretinograms and their response summation characteristics.
نویسندگان
چکیده
This study defined the amplitude and phase characteristics of rod- and cone-isolated flicker electroretinograms (ERGs) and determined how these responses summate to generate the nonreceptor-specific ERG. Full-field ERGs were obtained from six normally sighted subjects (age 26 to 44 years) using a four-primary LED-based photostimulator and standard recording techniques. The four primaries were either modulated sinusoidally in phase to achieve simultaneous rod and cone activation (ERGR+C; nonreceptor-specific) or in different phases to achieve rod-isolated (ERGR) and cone-isolated (ERGC) responses by means of triple silent substitution. ERGs were measured at two mean luminance levels (2.4 and 24 cd/m2), two contrasts (20 and 40%), and four temporal frequencies (2-15 Hz). Fundamental amplitude and phase for each condition were derived by Fourier analysis. Response amplitude and phase depended on the stimulus conditions (frequency, mean luminance, and contrast), however, for all conditions: 1) response phase decreased monotonically as stimulus frequency increased; 2) response amplitude tended to decrease monotonically as stimulus frequency increased, with the exception of the 24 cd/m2, 40% contrast ERGR+C that was sharply V-shaped; 3) ERGR phase was delayed (32 to 210 deg) relative to the ERGC phase; 4) ERGR amplitude was typically equal to or lower than the ERGC amplitude, with the exception of the 2.4 cd/m2, 40% contrast condition; and 5) the pattern of ERGR+C responses could be accounted for by a vector summation model of the rod and cone pathway signals. The results show that the ERGR+C amplitude and phase can be predicted from ERGR and ERGC amplitude and phase. For conditions that elicit ERGR and ERGC responses that have approximately equal amplitude and opposite phase, there is strong destructive interference between the rod and cone responses that attenuates the ERGR+C. Conditions that elicit equal amplitude and opposite phase rod and cone responses may be particularly useful for evaluating rod-cone interactions.
منابع مشابه
Properties of Flicker ERGs in Rat Models with Retinal Degeneration
Purpose. To describe the characteristics of rod and cone functions in rat models for congenital stationary night blindness (CSNB) and retinal cone dysfunction (RCD). Methods. Rod and cone function were isolated by recording the rod-/cone-driven flicker and blue light flicker electroretinograms (ERGs). Results. During dark adaptation, the amplitudes of flicker ERGs in CSNB rats were lower than t...
متن کاملThe Frequency-Response Electroretinogram Distinguishes Cone and Abnormal Rod Function in rd12 Mice
Early studies on Rpe65 knockout mice reported that remaining visual function was attributable to cone function. However, this finding has been challenged more and more as time has passed. Electroretinograms (ERGs) showed that rd12 mice, a spontaneous animal model of RPE65 Leber's congenital amaurosis, had sizeable photopic responses. Unfortunately, the recorded ERG waveform was difficult to int...
متن کاملRod Electroretinograms Elicited by Silent Substitution Stimuli from the Light-Adapted Human Eye
PURPOSE To demonstrate that silent substitution stimuli can be used to generate electroretinograms (ERGs) that effectively isolate rod photoreceptor function in humans without the need for dark adaptation, and that this approach constitutes a viable alternative to current clinical standard testing protocols. METHODS Rod-isolating and non-isolating sinusoidal flicker stimuli were generated on ...
متن کاملON-pathway dysfunction and timing properties of the flicker ERG in carriers of X-linked retinitis pigmentosa.
PURPOSE Carriers of X-linked retinitis pigmentosa (XLRP) frequently show prolonged implicit times of the flicker electroretinogram (ERG). This study tested the hypothesis that a preferential response attenuation within the cone depolarizing (ON) bipolar cell (DBC) pathway is a major contributing factor. METHODS Light-adapted, full-field ERGs were recorded from 10 XLRP carriers and 12 visually...
متن کاملElectroretinographic assessment of rod- and cone-mediated bipolar cell pathways using flicker stimuli in mice
Mouse full-field electroretinograms (ERGs) are dominated by responses of photoreceptors and depolarizing (ON-) bipolar cells, but not much of hyperpolarizing (OFF-) bipolar cells under conventional recording conditions. Here we investigate a novel ERG protocol in mice for functional assessment of the major ON- and OFF-bipolar cell pathways using flicker stimuli for a high luminance with varying...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Visual neuroscience
دوره 32 شماره
صفحات -
تاریخ انتشار 2015