Cardiac output monitoring by echocardiography: should we pass on Swan-Ganz catheters?

نویسنده

  • A. C. Perrino
چکیده

Transesophageal echocardiography offers a noninvasive technique for the continuous monitoring of cardiac performance. The combination of 2-dimensional echocardiography and Doppler velocitometry provide assessment of cardiac anatomy, valve function and, ventricular loading conditions. Although transesophageal echocardiography has become accepted for perioperative monitoring, it is typically used in conjunction with Swan-Ganz catheterization. To supplant Swan-Ganz catheters, an echocardiographic technique to monitor cardiac output is necessary. Despite considerable effort to achieve this goal, a satisfactory technique has been difficult to realize. This paper discusses the role of cardiac output monitoring in perioperative care and critically examines echocardiographic techniques for cardiac output monitoring.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Haemodynamic parameters obtained by transthoracic echocardiography and Swan-Ganz catheter: a comparative study in liver transplant patients.

OBJECTIVE To compare the haemodynamic measurements of cardiac output (CO), central venous pressure (CVP), pulmonary capillary wedge pressure (Pw) and pulmonary artery systolic pressure (PASP), obtained by Swan-Ganz catheter and transthoracic echocardiography. MATERIAL AND METHODS Prospective study in a Medical/Surgical Intensive Care Unit (ICU). A total of 41 post liver transplant patients we...

متن کامل

0866. Repercussion in hemodynamic values and extravascular lung water of alveolar recruitment maneuvers, in an experimental model of ARDS

C group Control group: without RA, using PEEP values bellow LIP (lower inflection point). The hemodynamic study (Heart rate, mean BP, PCP, PAP, CI), EVLW, and lactic acid, was made at basal time and at 15, 60, 180 and 360 minutes, after the provocation of ARDS. The catheters used for hemodynamic monitoring consisted in: venous catheters, arterial catheters and pulmonary artery catheter for dete...

متن کامل

Physiological changes of pregnancy and monitoring.

Advances in medical care have led to increasing numbers of complex, high-risk obstetric patients. Specialist training and a sound knowledge of normal maternal physiology are essential to optimize outcomes. One of the earliest observed changes is peripheral vasodilatation; this causes a fall in systemic vascular resistance and triggers physiological changes in the cardiovascular and renal system...

متن کامل

Doppler echocardiography in advanced systolic heart failure: a reliable noninvasive alternative to Swan-Ganz catheter

Background: Although several studies have demonstrated a good correlation between Doppler echocardiographic and invasive measurements of single hemodynamic variables, the accuracy of echocardiography in providing a comprehensive assessment in individual patients has not been validated. To assess the accuracy and clinical applicability of Doppler echocardiography in determining the entire hemody...

متن کامل

What technique should I use to measure cardiac output?

PURPOSE OF REVIEW Several less invasive cardiac output monitoring techniques are now commercially available and have the potential to replace the pulmonary artery catheter under certain clinical circumstances. The aim of this review is to give a synopsis of the currently available cardiac output measurement methods. This information should help in selecting the appropriate technique in a partic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Yale Journal of Biology and Medicine

دوره 66  شماره 

صفحات  -

تاریخ انتشار 1993