Calculation of Long Bone Loading Using Strain Gauges

نویسندگان

  • J. R. Funk
  • J. R. Crandall
چکیده

The standard methodology for measuring loads in long bones is the in situ load cell, which enables direct measurements, but alters the stiffness and mass of the subject bone. Bone loading can also be calculated by applying linear beam theory to measurements from strain gauges affixed to the bone surface. The efficacy of the strain gauge method was assessed in this study by mounting three strain gauge rosettes to the midshaft of the tibia in two cadaveric above-knee leg specimens. The specimens were subjected to quasistatic axial compression tests, and then the tibia was removed and subjected to four-point bending tests. Linear beam theory for an irregularly shaped cross-section was used to calculate the axial load and bending moments in the tibia. It was possible to accurately calculate the bending moments in the bone, but the calculated axial loads appeared to be grossly in error. The errors in the axial load results could be corrected by calculating an “effective” centroid for each bone, which was found to be approximately 1.5 mm away from the location of the area centroid as determined from CT scans. In spite of the error associated with calculating axial loads, this methodology shows promise for biomechanical experiments in which long bone bending is the parameter of greatest interest and implanting a load cell is problematic (e.g., vehicle-pedestrian tests).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental tests of planar strain theory for predicting bone cross-sectional longitudinal and shear strains.

Understanding of the diversity of skeletal loading regimes in vertebrate long bones during locomotion has been significantly enhanced by the application of planar strain theory (PST) to in vivo bone strain data. PST is used to model the distribution of longitudinal strains normal to the bone's transverse cross-section and the location of the neutral axis of bending. To our knowledge, the applic...

متن کامل

Investigation of Important Parameters in Residual Stress Determination in Isotropic Plates and Laminated Composites by Slitting Method

In the slitting method, a small width slit is created incrementally through the thickness of the stressed specimen and the released strains in each increment are recorded by a strain gauge. Compliance coefficients relate the measured strains to the residual stresses. This paper investigates the important parameters influencing the calculation of compliance coefficients for isotropic plates and ...

متن کامل

Evaluating Loading Deflection of Distraction Osteogenic Rib in a Rabbit Model

BACKGROUND The treatment of patients with partially atrophic rib and rib defects requires an ideal arc of the rib that has adequate bone length and width. To design and assemble a distraction device with a strain gauge, we need to establish an animal model for testing it during rib distraction osteogenesis. METHODS Osteotomies were performed at the same position in the fifth rib in 8 rabbits....

متن کامل

X. Wound and Fracture tai ng Stress Analysis of Internal Fracture Fixation of Long Bones

Progress Using mathematical models, we are investigating the influence of plate fixation on the internal stresses in long bones subjected to all known in vivo loading modes . The variables we are studying include : plate geometry, plate/bone fixity, and screw tightness. The mathematical models are based upon the finite element technique . The models will be subjected to all physiological loadin...

متن کامل

Structural behaviour and strain distribution of the long bones of the human lower limbs.

Although stiffness and strength of lower limb bones have been investigated in the past, information is not complete. While the femur has been extensively investigated, little information is available about the strain distribution in the tibia, and the fibula has not been tested in vitro. This study aimed at improving the understanding of the biomechanics of lower limb bones by: (i) measuring th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1980