Comparison Between Digital and Manual Marking for Toric Intraocular Lenses

نویسندگان

  • Abdel Hamid Elhofi
  • Hany Ahmed Helaly
  • Khaled Abdulrahman.
چکیده

To compare the clinical outcome of digital and manual marking for toric intraocular lens (IOL) alignment. This is a prospective clinical study that included 60 eyes of 60 patients undergoing cataract surgery with coexisting corneal astigmatism more than 1 diopter (D). The eyes were randomly assigned to either digital image guidance using VERION digital marker (Alcon Laboratories, Ft. Worth, TX) or manual slitlamp-assisted preoperative marking using pendulum-attached marker. Tecnis toric IOL (Abbott Medical Optics, Inc, Santa Ana, CA) was implanted in all cases. The mean postoperative uncorrected distance visual acuity (UCDVA) for the digital-marking group was 0.12 + 0.12 logMAR, and for the manual-marking group was 0.18 + 0.14 logMAR (P = 0.104). The mean deviation from targeted induced astigmatism (TIA) for the first group was 0.10 + 0.08 D and for the second group was 0.20 + 0.14 D (P = 0.001). The mean postoperative toric IOL misalignment measured by the slitlamp was 2.4° + 1.96° for the first group and was 4.33° + 2.72° for the second group (P = 0.003). Accurate alignment of the toric IOL is important to achieve the desired astigmatism correction. VERION system has the advantage of preoperative planning and intraoperative digital guidance of the toric IOL alignment. The use of VERION system resulted in less postoperative deviation from TIA and showed less postoperative toric IOL misalignment than using manual-marking technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surgical management of astigmatism with toric intraocular lenses.

Correction of corneal astigmatism is a key element of cataract surgery, since post-surgical residual astigmatism can compromise the patient's uncorrected visual acuity. Toric intraocular lenses (IOLs) compensate for corneal astigmatism at the time of surgery, correcting ocular astigmatism. They are a predictable treatment. However, accurate measurement of corneal astigmatism is mandatory for ch...

متن کامل

Sunalp YAG Laser Lens, A Novel Method for Marking the Axis of Astigmatism Before Cataract Surgery and Toric Lens Implantation

Purpose: Comparison of astigmatic correction and visual acuity outcomes in patients implanted with toric intraocular lenses following cataract surgery reference marked pre-operatively manually with a pen or with YAG laser, in conjunction with the Sunalp YAG Laser Lens. Methods: 16 eyes from 16 patients were divided into two groups of 8 patients each. Pre-operativelly, the eye of one group was r...

متن کامل

Evaluation of rotation and visual outcomes after implantation of monofocal and multifocal toric intraocular lenses.

PURPOSE To evaluate rotational stability and its influence on postoperative visual acuity of different monofocal and multifocal toric intraocular lenses (IOLs). METHODS A prospective interventional study was designed. Ninety-one patients with a mean age of 71.65 ± 11.82 years were implanted with toric IOLs after phacoemulsification. Three monofocal toric IOLs (the Lentis LT [Oculentis, Berlin...

متن کامل

IOLMaster keratometry for the calculation of toric intraocular lens power and orientation

In the implantation of intraocular lenses (IOL) stringent requirements are made on achieving the refractive target. This necessitates the exact determination of the basic data needed for IOL power calculation – both the axial length and, in particular, the corneal power – and additionally the cylinder power and its axis in the case of a toric lens. This gives rise to the question, especially fo...

متن کامل

Which Keratometer is Most Reliable for Correcting Astigmatism with Toric Intraocular Lenses?

PURPOSE To evaluate the accuracy of preoperative keratometers used in cataract surgery with toric intraocular lens (IOL). METHODS Twenty-five eyes received an AcrySof toric IOL implantation. Four different keratometric methods, a manual keratometer, an IOL master, a Pentacam and an auto keratometer, were performed preoperatively in order to evaluate preexisting corneal astigmatism. Difference...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 94  شماره 

صفحات  -

تاریخ انتشار 2015