First Metatarsalphalangeal Joint Arthrodesis: A Retrospective Comparison of Two Methods of Fixation
نویسندگان
چکیده
First metatarsalphalangeal joint arthrodesis is a well established and successful treatment; however there still remains controversy over the best choice of construct. We performed a retrospective study of patients undergoing first metatarsalphalangeal fusion over eighteen months (n=52) using either dorsal non-locking plate with additional compression lag screw fixation or dorsal non-locking plate alone. We found when assessing clinical criteria, patients with dorsal non-locking plates and additional compression lag screw fixation had a significantly higher rate of fusion (100% vs 77.8%), significantly higher rate of fusion within the first two months (55.6% vs 83.3%), significantly earlier time to fusion (52.2 days vs 75.6 days), and significantly lower rate of non-union (0% vs 22.2%). When blindly assessing radiographic criteria, the patients treated with the plate and compression screw had a significantly higher rate of fusion and lower rate of non-union (0% vs 33%). There was no statistically significant difference between the frequencies of complications in the groups. We believe that the interfragmentary compression is a crucial factor in achieving good union rates and recommend the use of non-locking pre-contoured plating with additional interfragmentary compression screw as the fixation method of choice for these procedures.
منابع مشابه
First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw
Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...
متن کاملFirst Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw
Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...
متن کاملFirst Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw.
BACKGROUND Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. There are still few comparable clinical data regarding this procedure. In this study we aimed to compare the clinical and radiographical outcomes of crossed-screws, locking and non-locking plate fixation with lag screw for first metatarsophalangeal joint arthrodesis. METHODS A total...
متن کاملAnterior Ankle Arthrodesis with Molded Plate: Technique and Outcomes
Background: There is still controversy regarding the best technique for ankle arthrodesis to acheive stable rigid fixation along with reconstructing a functional plantigrade foot. Moreover, existing techniques have complictions related to stability, soft tissue covering, fusion rate, and exposure. Methods: With the anterior approach exactly on the tibialis anterior sheath, the joint was expose...
متن کاملCost-effectiveness comparison of three methods of internal fixation for arthrodesis of the first metatarsophalangeal joint.
We used decision-analysis modeling to determine the most cost-effective fixation device among Herbert screws, AO screws, and the Luhr plate for first metatarsophalangeal joint arthrodesis. The model considered patient-reported outcomes at minimum 2-year follow-up, patient charges for the entire course of care, and event and outcome incidences within each fixation group. AO screws had the lowest...