Effect of Different Rotational Directions of BJUT-II VAD on Aortic Swirling Flow Characteristics: A Primary Computational Fluid Dynamics Study

نویسندگان

  • Qi Zhang
  • Bin Gao
  • Yu Chang
چکیده

BACKGROUND The BJUT-II VAD is a novel left ventricular assist device (LVAD), which is thought to have significant effects on the characteristics of aortic swirling flow. However, the precise mechanism of the rotational direction of BJTU-II VAD in the aortic swirling flow is unclear. MATERIAL AND METHODS A patient-specific aortic geometric model was reconstructed based on the CT data. Three pump's output flow profiles with varied rotational direction, termed "counterclockwise", "flat profile", and "clockwise", were used as the boundary conditions. The helicity density, area-weighted average of helicity density (Ha), localized normalized helicity (LNH), wall shear stress (WSS), and WSS spatial gradient (WSSG) were calculated to evaluate the swirling flow characteristics in the aorta. RESULTS The results demonstrated that the swirling flow characteristics in the aorta and 3 branches are directly affected by the output blood flow of BJUT-II VAD. In the aortic arch, the helicity density, supported by the clockwise case, achieved the highest value. In the 3 branches, the flat profile case achieved the highest helicity density, whereas the maximum WSS and WSSG generated by clockwise case were lower than in other cases. CONCLUSIONS The outflow of the BJUT-II VAD has significant effects on the aortic hemodynamics and swirling flow characteristics. The helical blood profiles can enhance the strength of aortic swirling flow, and reduce the areas of low WSS and WSSG regions. The clockwise case may have a benefit for preventing development of atherosclerosis in the aorta.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulsatile Support Mode of BJUT-II Ventricular Assist Device (VAD) has Better Hemodynamic Effects on the Aorta than Constant Speed Mode: A Primary Numerical Study

BACKGROUND BJUT-II VAD is a novel left ventricular assist device (LVADs), directly implanted into the ascending aorta. The pulsatile support mode is proposed to achieve better unloading performance than constant speed mode. However, the hemodynamic effects of this support mode on the aorta are still unclear. The aim of this study was to clarify the hemodynamic effects BJUT-II VAD under pulsatil...

متن کامل

Computational fluid dynamics study and GA modeling approach of the bend angle effect on thermal-hydraulic characteristics in zigzag channels

In the study, the thermal-hydraulic performance of the zigzag channels with circular cross-section was analyzed by Computational Fluid Dynamics (CFD). The standard K-Ꜫ turbulent scalable wall functions were used for modeling. The wall temperature was assumed constant 353 K and water was used as the working fluid. The zigzag serpentine channels with bend angles of 5 - 45° were studied for turbul...

متن کامل

Computational Analysis of Intra-Ventricular Flow Pattern Under Partial and Full Support of BJUT-II VAD

BACKGROUND Partial support, as a novel support mode, has been widely applied in clinical practice and widely studied. However, the precise mechanism of partial support of LVAD in the intra-ventricular flow pattern is unclear. MATERIAL AND METHODS In this study, a patient-specific left ventricular geometric model was reconstructed based on CT data. The intra-ventricular flow pattern under 3 simu...

متن کامل

Multiphase flow and tromp curve simulation of dense medium cyclones using Computational Fluid Dynamics

Dense Medium Cyclone is a high capacity device that is widely used in coal preparation. It is simple in design but the swirling turbulent flow, the presence of medium and coal with different density and size fraction and the presence of the air-core make the flow pattern in DMCs complex. In this article the flow pattern simulation of DMC is performed with computational fluid dynamics and Fluent...

متن کامل

Experimental and Computational Study on Hydrodynamic of a Downscaled Mini Vessel USP Dissolution Test Apparatus II

Although not listed on the United States Pharmacopeia (USP), like standard USP 2, small volume USP 2 dissolution apparatus has gained a great deal of attention, especially for cases where small amount of drug product is available for testing in research and design step or evaluations are to be made on a tablet containing trace amounts of the active pharmaceutical ingredient. In this work, first...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 22  شماره 

صفحات  -

تاریخ انتشار 2016