The purpose of this study was to elucidate the difference in inotrope use between patients who underwent left ventricular assist device (LVAD) implantation with preoperative extracorporeal membrane oxygenation (ECMO) and those who underwent LVAD implantation without preoperative ECMO. One hundred and eight patients who underwent LVAD implantation were enrolled in this study. Prior to LVAD implantation, 27 patients received ECMO support (ECMO group) and the other 81 patients did not (non-ECMO group). Cardiac index (CI), mean arterial pressure (MAP), mixed venous oxygen saturation (SvO2), and the vasoactive inotropic score (VIS) were recorded at weaning from cardiopulmonary bypass (CPB), 30 min after weaning from CPB (min after CPB), 60 min after CPB, and at the end of surgery. MAP and VIS were also recorded before induction of anesthesia (baseline). The modified VIS was defined as: (dopamine µg/kg/min × 1 + dobutamine µg/kg/min × 1 + epinephrine µg/kg/min × 100 + noradrenaline µg/kg/min × 100 + milrinone µg/kg/min × 10 + olprinone µg/kg/min × 25). There were no significant differences between the ECMO group and the non-ECMO group in terms of hemodynamic parameters such as MAP, CI, and SvO2. However, the ECMO group had higher VIS and noradrenaline doses than that of non-ECMO group (p = 0.030 and p = 0.044, respectively). VIS was significantly higher in ECMO group at 30 min after CPB (p = 0.03), 60 min after CPB (p = 0.003), and at the end of the surgery (p < 0.001). The doses of noradrenaline were significantly higher in ECMO group at 60 min after CPB (p = 0.013), and at the end of surgery (p = 0.002). Patients who received ECMO support prior to LVAD implantation required significantly more noradrenaline to maintain normal levels of hemodynamic parameters compared with patients without ECMO.
منابع مشابه
Prophylactic Intra-Aortic Balloon Pump Before Ventricular Assist Device Implantation Reduces Perioperative Medical Expenses and Improves Postoperative Clinical Course in INTERMACS Profile 2 Patients.
BACKGROUND Although intra-aortic balloon pump (IABP) is sometimes used before cardiac surgery to achieve better outcome in high-risk patients, the clinical impact of prophylactic IABP support before left ventricular assist device (LVAD) implantation in patients with worsening hemodynamics was unknown. METHODSANDRESULTS We enrolled 22 patients with worsening hemodynamics who had received IABP ...
متن کاملExtracorporeal membrane oxygenation as perioperative right ventricular support in patients with biventricular failure undergoing left ventricular assist device implantation.
OBJECTIVE Left-ventricular assist device (LVAD) implantation complicated by early right ventricle (RV) failure has a poor prognosis. This study details our center's experience with veno-arterial extracorporeal membrane oxygenation (ECMO) as perioperative RV support in patients with preoperative biventricular failure undergoing LVAD implantation. METHODS Ten patients, who underwent LVAD implan...
متن کاملImplantation of left ventricular support under extracorporeal membrane oxygenation.
Continuous-flow left ventricular assist devices (LVADs) are used to manage patients with end-stage heart failure. Protection of right ventricular (RV) function is important during LVAD implantation, but sometimes patients require temporary RV support. We describe the technique of LVAD implantation under extracorporeal membrane oxygenation (ECMO) we use in our center. This technique allows soft ...
متن کاملSuccessful extracorporeal membrane oxygenation weaning after cardiac resynchronization therapy device implantation in a patient with end-stage heart failure.
We present the case of a 46-year old male with end-stage heart failure due to ethyltoxic cardiomyopathy. The patient did not meet the criteria for heart transplantation and declined left ventricular assist device implantation. We decided to conduct cardiac resynchronization therapy defibrillator (CRT-D) implantation. Under general anaesthesia for CRT-D implantation, cardiac function worsened. D...
متن کاملBailout transcatheter closure of patent foramen ovale for refractory hypoxaemia after left ventricular assist device implantation.
We describe the interdisciplinary management of a 59-year old man with ischaemic cardiomyopathy on a HeartMate II left ventricular assist device (LVAD) and temporary right extracorporeal membrane oxygenation (ECMO) as a bridge-to-heart transplantation. He suffered refractory hypoxaemia due to massive right-to-left shunting by a patent foramen ovale (PFO), diagnosed after weaning off of temporar...