Combined fat- and water-suppressed MR imaging of orbital tumors.

نویسندگان

  • A Jackson
  • S Sheppard
  • A C Johnson
  • D Annesley
  • R D Laitt
  • A Kassner
چکیده

BACKGROUND AND PURPOSE The use of a high-resolution T2-weighted MR sequence, which suppresses signal from both fat and water, has been shown to be highly effective for depicting areas of inflammatory damage within the optic nerve. The ability of this sequence to show neoplastic and inflammatory orbital lesions, which may mimic neuritis, is unknown. This study was designed to examine the characteristics of such a sequence for the investigation of orbital mass lesions. METHODS Twenty-eight patients with known or suspected mass lesions of the orbit and six healthy volunteers were recruited for study. Imaging was performed with a 1.5-T MR unit. Participants were examined by selective partial inversion recovery (SPIR) sequences with T2-weighted fast spin-echo acquisition, selective partial inversion recovery/fluid attenuated inversion recovery (SPIR/FLAIR) sequences with fast spin-echo acquisition, short tau inversion recovery (STIR) sequences with fast spin-echo acquisition, and SPIR sequences with contrast-enhanced T1-weighted fast spin-echo acquisition. Two neuroradiologists, using a randomised, blinded method, scored images for lesion presence and extent. Lesion extent was defined as the number of images with visible abnormality, and was compared with the standard of reference established at a later date by consensus review of all imaging sequences. The ability of the sequences to show the presence and extent of pathologic lesions was compared. RESULTS The SPIR/FLAIR sequence showed both the presence and extent of orbital masses significantly better than did either STIR or T2-weighted SPIR sequences (P<.01 and P<.001, respectively). Contrast-enhanced T1-weighted SPIR images ranked better than SPIR/FLAIR images, although the difference failed to reach statistical significance. In the orbital apex, the SPIR/FLAIR technique was superior to all other techniques used. This reflected its ability to distinguish enhancing, pathologic lesions from enhancing, normal anatomy. CONCLUSION SPIR/FLAIR is an appropriate screening technique for orbital masses and offers significant advantages over currently used fat-suppressed sequences for the investigation of orbital disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dynamic Contrast Magnetic Resonance Imaging (DCE-MRI) and Diffusion Weighted MR Imaging (DWI) for Differentiation between Benign and Malignant Salivary Gland Tumors

Background: Salivary gland tumors form nearly 3% of head and neck tumors. Due to their large histological variety and vicinity to facial nerves, pre-operative diagnosis and differentiation of benign and malignant parotid tumors are a major challenge for radiologists. Objective: The majority of these tumors are benign; however, sometimes they tend to transform into a malignant form. Functional M...

متن کامل

Intra- and paraorbital lesions: value of fat-suppression MR imaging with paramagnetic contrast enhancement.

The orbital area of 18 individuals was examined by using a combination of fat-suppression contrast-enhanced MR imaging to determine whether contrast between fat and surrounding tissues could be improved over that obtained with conventional fat-suppression techniques alone. We used a hybrid technique combining two independent methods of fat suppression. Subjects consisted of 16 patients and two ...

متن کامل

Fat - Suppression MR Imaging of the Orbit 961

The effect of fat suppression on orbital MR imaging was tested by using a derivative of the Dixon method called chopper fat suppression in eight normal volunteers and eight patients with normal conventional orbital MR studies. Chopper fat suppression requires no postacquisition image processing or increased scan time and can be applied through a wide range of n to T2 weighting. In normal orbits...

متن کامل

Fat-suppressed MR of the orbit and cavernous sinus: comparison of fast spin-echo and conventional spin-echo.

PURPOSE To compare T2-weighted fat-suppressed fast spin-echo imaging with fat-suppressed conventional spin-echo imaging in the detection of normal intraorbital and pericavernous anatomy and orbital disease, and to determine the efficacy of fat saturation with T2-weighted fast spin-echo imaging of the cavernous sinus. METHODS Contrast-to-noise ratios of normal intraorbital anatomy were calcula...

متن کامل

Fat Suppressed FSE Pelvic MR Imaging with Two New FSE Based Dixon Pulse Sequences: A Comparison of IDEAL FSE and FSE Triple Echo Dixon

Background: Fat suppressed FSE T2-weighted imaging is an integral part of an MR pelvic examination. However, fat suppression by conventional technique can be degraded by inhomogeneities of the magnetic field. The problem can be exacerbated when a typical large FOV is used for abdominal and pelvic imaging. Techniques that provide fat-suppressed T2-weighted imaging that is insensitive to field in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 20 10  شماره 

صفحات  -

تاریخ انتشار 1999