Determining when to measure vascular access flow …that may not be enough
نویسندگان
چکیده
Vascular access in hemodialysis patients is crucial. Vascular access monitoring to ensure access patency is important for patient survival, quality of life, and blood vessel care. The ultrasound dilution method for measuring access flow is a screening tool to assess access dysfunction. Park et al. [1] performed a single-center prospective study of the variation in access flow during hemodialysis, and we have some questions and comments. The study showed the effects of intradialytic change in blood pressure and ultrafiltration volume on the variation in access flow. As the authors mentioned, access flow measurement is useful for vascular access surveillance. However, what canwe predict based on the variable flows?We doubt whether the flow variation could help to predict vascular access events. If patient data for vascular access events (thrombosis or stenosis) were available, the authors would have more informative results. According to the study reported by Park et al [1], the mean vintage of access was almost 5 years with a wide range of distribution. Because the duration of dialysis may influence the vascular patency and blood flow, previous studies enrolled only the incident hemodialysis patients [2,3]. The sample size in the study by Park et al [1] was too small to adjust for the duration of dialysis. Finally, the heterogeneity of vascular access should have been considered in the data interpretation. Because arteriovenous grafts and native fistulae have completely different physiologies, different cutoff values for vascular patency have been recommended according to the vascular access type [3].
منابع مشابه
Invasive radiologic management of hemodialysis fistulas: measuring flow with an endovascular catheter.
OBJECTIVES To analyze the values of flow obtained with an endovascular catheter, and to determine whether they are more reliable than angiographic and clinical findings for planning and for determining the outcome of invasive radiologic treatment of hemodialysis fistulas, as well as to determine the safety of this technique during interventional radiology procedures. MATERIAL AND METHODS We u...
متن کاملTHE EFFECT OF EVIDENCE-BASED EDUCATION ON THE KNOWLEDGE OF NURSING STUDENTS IN THE CARE OF HEMODIALYSIS VASCULAR ACCESS
Background & Aim: One of the basic and important needs of hemodialysis patients is vascular access. Nursing students as members of the health team and future nurses, play an essential role in the safety management of hemodialysis patients and therefore, their training is important to support patient safety. Today, evidence-based education with the objective of explicit and rational use of the b...
متن کاملComparison of the effect of rinsing the vascular access site for hemodialysis with Betadine scrub and soap by patient on the frequency and onset of local inflammation and infection
Background: Despite the implementation of nursing measures in disinfecting the vascular access site for hemodialysis, this area is responsible for 23 to 73 percent of bacteremias occurring in these patients. Participation of the patients in washing this area may be helpful. Aim: this study was conducted to determine and compare the effect of washing vascular access site for hemodialysis with ...
متن کاملAlterations in the vascular β-adrenoceptors of the rabbit knee joint due to acute inflammation
It has been shown that acute inflammation reduces the effectiveness of sympathetic nerves in the regulation of knee joint blood flow. To investigate the role of vascular β- adrenoceptors in this event, 12 NZW rabbits were maintained anaesthetized by 1 % halothane in N2O/O2, and acute knee joint inflammation was induced by intra-articular injection of 1 ml of 2% carageenan solution 24 hours be...
متن کاملRole of Bradykinin and Mas Receptor Blockade in Renal Vascular Responses to Angiotensin 1-7 in Adult Female Rats
Background and purpose: Chronic kidney disease is among the common diseases in the world. Studies show that women are more protected against renal diseases compared to men. On the other hand, vasodilatory axises of renin angiotensin system (angiotensin 1-7 (Ang 1-7)- Mas receptor (MasR)), kallikrein-kinin, and nitric oxide (NO) play key roles in kidney function and circulation in females. There...
متن کامل