Detection of Salmonella typhimurium using an electrochemical immunosensor.
نویسندگان
چکیده
An electrochemical immunosensor based on screen-printed gold working electrode with onboard carbon counter and silver-silver chloride pseudo-reference electrode for Salmonella typhimurium detection is described in this paper. Monoclonal anti-S. typhimurium antibody was immobilized using physical and covalent immobilization via amine coupling of carboxymethyldextran on the surface of the gold working electrode. A direct sandwich enzyme-linked immunosorbent assays (ELISA) format was then developed and optimized using a polyclonal anti-Salmonella antibodies conjugated to horseradish peroxidase (HRP) as the enzyme label. 3,3',5,5'-Tetramethylbenzidine dihydrochloride (TMB)/H(2)O(2) was used as the enzyme mediator/substrate system. Electrochemical detection was conducted using chronoamperometry at -200 mV vs. onboard screen-printed Ag-AgCl pseudo-reference electrode. The applied potential was selected through the study of the electrochemical behaviour of bare gold electrode with TMB-H(2)O(2)-IgG-HRP system. S. typhimurium detection of 5x10(3) cells ml(-1) and approximately 20 cells ml(-1) was achieved respectively for physical and covalent antibody immobilization. The developed sensor was then compared to a commercial ELISA kit and a chromogenic agar plating method for meat samples analysis. The sensor format shows a promising technology for simple and sensitive detection system for Salmonella contamination. Rapid detection of Salmonella is a key to the prevention and identification of problems related to health and safety.
منابع مشابه
Label-free as-grown double wall carbon nanotubes bundles for Salmonella typhimurium immunoassay
BACKGROUND A label-free immunosensor from as-grown double wall carbon nanotubes (DW) bundles was developed for detecting Salmonella typhimurium. The immunosensor was fabricated by using the as-grown DW bundles as an electrode material with an anti-Salmonella impregnated on the surface. The immunosensor was electrochemically characterized by cyclic voltammetry. The working potential (100, 200, 3...
متن کاملFabrication of an Electrochemical Immunosensor for Determination of Human Chorionic Gonadotropin Based on PtNPs/Cysteamine/AgNPs as an Efficient Interface
An ultrasensitive electrochemical immunosensor for the detection of tumor marker human chorionic gonadotropin (hCG) was developed with a limit of detection as low as 2 pg mL-1 in phosphate buffer. The Platinum nanoparticles (PtNPs) were electrodeposited to modify the gold surface and to increase enlarging the electrochemically active sites, resulting in the facilitation of electron exchange. Cy...
متن کاملA Portable Impedance Immunosensing System for Rapid Detection of Salmonella Typhimurium
SalmonellaTyphimurium is one of the most dangerous foodborne pathogens and poses a significant threat to human health. The objective of this study was to develop a portable impedance immunosensing system for rapid and sensitive detection of S. Typhimurium in poultry. The developed portable impedance immunosensing system consisted of a gold interdigitated array microelectrode (IDAM), a signal ac...
متن کاملUsing Boehmite Nanoparticles as an Undercoat, and Riboflavin as a Redox Probe for Immunosensor Designing: Ultrasensitive Detection of Hepatitis C Virus Core Antigen
In this study a label-free electrochemical Immunosensor for ultrasensitive detection of Hepatitis C virus core antigen in serum samples was fabricated by using a simple approach. In this method a low-cost and sensitive immunosensor was fabricated based on a boehmite nanoparticles (BNPs) modified glassy carbon. The BNPs provide a specific platform with increased surface area which is capable of ...
متن کاملLabel-free ITO-based immunosensor for the detection of very low concentrations of pathogenic bacteria.
Here we describe the fabrication of a highly sensitive and label-free ITO-based impedimetric immunosensor for the detection of pathogenic bacteria Escherichia coli O157:H7. Anti-E. coli antibodies were immobilized onto ITO electrodes using a simple, robust and direct methodology. First, the covalent attachment of epoxysilane on the ITO surface was demonstrated by Atomic Force Microscopy and cyc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biosensors & bioelectronics
دوره 24 8 شماره
صفحات -
تاریخ انتشار 2009