Performance of presbyopia-correcting intraocular lenses in distance optical bench tests.

نویسندگان

  • W Andrew Maxwell
  • Stephen S Lane
  • Fan Zhou
چکیده

PURPOSE To compare the optical performance of 6 presbyopia-correcting intraocular lenses (IOLs) of different designs (accommodating or multifocal and aspheric or spheric). SETTING Alcon Laboratories, Inc., Fort Worth, Texas, USA. METHODS The optical performance of 6 IOLs were compared using modulation transfer function (MTF) and the United States Air Force 1951 Resolution Target (AFT) testing. The IOLs included 3 spheric designs (Crystalens AT-50SE, AcrySof ReSTOR SA60D3, and ReZoom NXG1) and 3 aspheric designs (AcrySof ReSTOR SN6AD3, Acri.Lisa 366D, and Tecnis ZM900). Tests were performed with a modified International Organization for Standardization (ISO) model eye with a 5.0 mm aperture at the distance focus. RESULTS The ReSTOR aspheric IOL had the highest MTF values at all spatial frequencies, and the ReZoom IOL had the lowest MTF values at most spatial frequencies. The ReSTOR aspheric IOL produced the image with the highest resolution on the AFT test; the Tecnis and the ReZoom IOLs produced the images with the poorest resolution. The Acri.Lisa multifocal IOL was second to the ReSTOR aspheric IOL on the MTF test and had high resolution on the AFT test. The accommodating Crystalens performed poorly on the MTF test but had the second highest resolution on the AFT test. CONCLUSIONS The AcrySof ReSTOR SN6AD3 aspheric IOL showed superior optical properties, demonstrated in MTF and AFT optical bench testing, among 6 presbyopia-correcting IOLs including the monofocal accommodating Crystalens. The Acri.Lisa IOL also performed well. The ReZoom IOL demonstrated the poorest overall optical quality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Causes and correction of dissatisfaction after implantation of presbyopia-correcting intraocular lenses

PURPOSE The purpose of this study was to assess the causes and possible solutions for patient dissatisfaction after the implantation of presbyopia-correcting intraocular lenses (IOLs). METHODS This study was a retrospective review of clinical records. All patients who were seen between January 2009 and December 2013 whose primary reason for consultation was dissatisfaction with visual perform...

متن کامل

Optical bench performance of a novel trifocal intraocular lens compared with a multifocal intraocular lens

PURPOSE The purpose of this study is to compare the optical characteristics of the novel PanOptix presbyopia-correcting trifocal intraocular lens (IOL) and the multifocal ReSTOR +3.0 D IOL, through in vitro bench investigations. METHODS The optical characteristics of AcrySof(®) IQ PanOptix™ (PanOptix) and AcrySof(®) IQ ReSTOR +3.0 D (ReSTOR +3.0 D) IOLs were evaluated by through-focus Badal i...

متن کامل

Comparison of through-focus image quality across five presbyopia-correcting intraocular lenses (an American Ophthalmological Society thesis).

PURPOSE To assess through-focus polychromatic image sharpness of five US Food and Drug Administration-approved presbyopia-correcting intraocular lenses (IOLs) through a range of object vergences and pupil diameters utilizing an image sharpness algorithm. METHODS A 1951 US Air Force resolution target was imaged through a Crystalens AO (AO) (Bausch & Lomb Surgical, Aliso Viejo, California), Cry...

متن کامل

Multifocal intraocular "mix and match" lenses.

The new generation multifocal lenses provide the surgeon with several options to meet the specific visual needs and desires of patients. A revolution in presbyopia surgery is being driven by two multifocal intraocular lenses, ReStor and ReZoom. Combined implantation of the ReZoom multifocal lens in nondominant eye and ReStor multifocal lens in dominant eye has been demonstrated to produce stati...

متن کامل

Prospective evaluation of visual outcomes with three presbyopia-correcting intraocular lenses following cataract surgery

PURPOSE To compare the visual acuity and quality of vision achieved with three widely-used intraocular lenses (IOLs) in subjects with bilateral cataracts. PATIENTS AND METHODS This three-arm, parallel, prospective, partially masked, single-surgeon study randomized 78 subjects to receive bilateral Crystalens® Advanced Optics (AO) accommodating IOLs, AcrySof® IQ ReSTOR® +3.0 multifocal IOLs, or...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 35 1  شماره 

صفحات  -

تاریخ انتشار 2009