Intermittent cardiogenic shock in a man with mechanical prosthesis of the aortic valve.

نویسندگان

  • Vojtech Melenovsky
  • Hikmet Al Hiti
  • Petr Lupinek
  • Tomas Marek
  • Tomas Veiser
  • Ivo Skalsky
  • Jiri Kettner
چکیده

Intermittent dysfunction of prosthetic aortic valve is a rare but life-threatening condition that may be difficult to recognize. Here, we present a case of 64-year-old man with a history of bicuspid aortic valve that had been replaced with a Medtronic-Hall prosthesis 15 years earlier. Until his current illness, he was fit, with good function of the valve and well maintained anticoagulation. After several days of progressive intermittent breathlessness, he experienced severe anginal chest pain, orthopnea, and dizziness that proceeded into an electromechanical dissociation. Circulation was restored after a brief resuscitation, intubation, and the administration of vasopressors by emergency medical services personnel. On admission to the intensive care unit, he had sinus rhythm with intraventricular conduction defect (Figure 1), stable blood pressure on vasopressors, and was ventilated for pulmonary edema (Figure 2). Nongated chest computed tomography scan ruled out an aortic dissection, and no particular abnormality was observed in the area of the aortic valve, although the resolution in the closest proximity of the prosthesis was attenuated by artifacts. Echocardiography showed normal right ventricular size/function, mild systolic left ventricular dysfunction, aortic valve prosthesis with a small systolic gradient (30/20 mm Hg) and negligible insufficiency (1/5), and no thrombus/mass within the prosthesis (Figure 3B). Troponin I was elevated (140 g/L), but angiography (Movies I and II in the online-only Data Supplement) showed normal coronary anatomy and normal motion of the prosthetic disc. The cause of hemodynamic collapse remained unexplained. The condition of the patient improved, but the next day, after an attempt to taper norepinephrine infusion, he developed multiple episodes of sudden and profound hypotension, terminated by bolus-dosed norepinephrine (Figure 3D). During one of such episodes, we noticed an abrupt change of invasive arterial pressure waveform with diastolic flattening (Figure 3A), coinciding with a disappearance of audible click of the valve. At this time, bedside echocardiography confirmed massive aortic regurgitation from the incompletely closed aortic prosthesis (Figure 3C and 3D; Movies III and IV in the online-only Data Supplement). Transesophageal echocardiography (Movie V in the online-only Data Supplement; Figure 4) identified a nonobstructing rod-like protrusion bellow the valve plane formed by pannus (arrow, Figure 4), and small filiform thrombus, superimposed on the base of the pannus (visible in Movie V). These structures probably

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Successful Use of Two Thrombolytic Drugs in Prosthetic Mitral and Aortic Valve Thrombosis

Introduction: Prosthetic valve thrombosis is a rare and severe complication of valve replacement, most often encountered with a mechanical prosthesis. The significant morbidity and mortality associated with this condition warrant rapid diagnostic evaluation. Although surgery is the first-line therapy in symptomatic obstructive mechanical valve thrombosis, thrombolytic therapy has been used as a...

متن کامل

Aortic Valve replacement with Reduction Aortoplasty with Mesh Prosthesis in 75 years old with Sever aortic Regurgitation with Aortic Aneurysm

Although classic and standard procedure for patients with ascending Aorta aneurysm with Sever aortic Regurgitation is Bentall surgery but in some selected cases this complex surgery was not performed with different reason like advanced age and coexisting comorbidity involving renal and hepatic and lung Function. In our cases 75 years old man with chronic renal failure ( Cr= 3.2 ) who was known ...

متن کامل

Left main coronary artery occlusion due to thrombus embolization from a prosthetic mitral valve.

A 46-year-old woman with a history of rheumatic heart disease and mitral and aortic valve replacement with mechanical bileaflet prosthesis was admitted with acute anterior wall ST-segment elevation myocardial infarction and cardiogenic shock after discontinuation of anticoagulant therapy. She underwent emergency coronary catheterization. Fluoroscopy confirmed normal motion of the prosthetic val...

متن کامل

مقایسه اندازه دریچه آئورت مصنوعی نصب شده با قطر رینگ دریچه آئورت به طریقه اکوکاردیوگرافی دو بعدی بمنظور پیش بینی اندازه دریچه مصنوعی آئورت قبل از عمل جراحی

In recent socio-economic state it is not possible to have different sets of prosthetic cardiac valves available in the operating room before open-heart surgery for valvular replacement. In this study the diameter of the aortic valve ring measured in 2-D echocardiography was compared with the size of the aortic prosthetic valves implanted for the patients with aortic valvular disease. The purpos...

متن کامل

Aortic valve replacement with different types of prosthesis: are there differences in the outcomes during hospital phase?

OBJECTIVE To analyze intraoperative data and possible differences in clinical evolution during postoperative hospital phase for aortic valve replacement surgery using different types of prosthesis. METHODS Analysis of 60 patients divided into three groups. Valve replacement with bioprosthesis (20), mechanical prosthesis (20) and homologous valve (20). The mean age was 51.1, 60% were male and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 124 1  شماره 

صفحات  -

تاریخ انتشار 2011