Analysis of setup error based on CTVision for nasopharyngeal carcinoma during IGRT

نویسندگان

  • Shuxu Zhang
  • Xiang Zhou
  • Quanbin Zhang
  • Shaohui Jiang
  • Ruihao Wang
  • Guoqian Zhang
  • Huaiyu Lei
  • Shengqu Lin
چکیده

The aim of the present study was to investigate the role of CTVision in interfractional setup errors during intensity-modulated radiation therapy (IMRT) in 12 nasopharyngeal carcinoma (NPC) patients. The trend of setup errors as a function of time during a fractionated radiotherapy course was investigated, and the influence of reconstructive thickness on image reconstruction for setup errors was analyzed. The appropriate planning target volume (PTV) margin and planning risk volume (PRV) margin were defined to provide a reference for the design of IMRT for NPC. Based on CTVision, online CT was performed weekly for each patient. Setup errors were measured by registration between the CT reconstructed image and reference image. Mean of setup errors, estimated population systematic (Σ), and population random (σ) errors were calculated using SPSS (v15.0). Optimum PTV and PRV margins were calculated. In the clinical data, for the LR (left-right), SI (superior-inferior), and AP (anterior-posterior) directions, Σ was 0.8, 0.8, and 1.0 mm, respectively, and σ was 1.0, 1.3, and 0.8 mm, respectively. In the LR, SI, and AP directions, PTV margins were at least 2.7, 2.9, and 3.0 mm, respectively, and PRV margins were at least 1.5, 1.7, and 1.7 mm, respectively. No significant differences in setup errors were observed during the fractionated radiotherapy course (p > 0.05). However, CT image reconstruction with different thicknesses affected the accuracy of measurements for setup errors, particularly in the SI direction. The application of CTVision to correct setup errors is important and can provide reasonable margins to guarantee the coverage of PTVs and spare organs at risk. A thickness of 3 mm in the reconstructed image is appropriate for the measurement of setup errors by image registration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inter- and intrafraction uncertainty in prostate bed image-guided radiotherapy.

PURPOSE The goals of this study were to measure inter- and intrafraction setup error and prostate bed motion (PBM) in patients undergoing post-prostatectomy image-guided radiotherapy (IGRT) and to propose appropriate population-based three-dimensional clinical target volume to planning target volume (CTV-PTV) margins in both non-IGRT and IGRT scenarios. METHODS AND MATERIALS In this prospecti...

متن کامل

Different setup errors assessed by weekly cone-beam computed tomography on different registration in nasopharyngeal carcinoma treated with intensity-modulated radiation therapy

The study aimed to investigate the difference of setup errors on different registration in the treatment of nasopharyngeal carcinoma based on weekly cone-beam computed tomography (CBCT). Thirty nasopharyngeal cancer patients scheduled to undergo intensity-modulated radiotherapy (IMRT) were prospectively enrolled in the study. Each patient had a weekly CBCT before radiation therapy. In the entir...

متن کامل

Setup Error and Effectiveness of Weekly Image-Guided Radiation Therapy of TomoDirect for Early Breast Cancer

PURPOSE This study investigated setup error and effectiveness of weekly image-guided radiotherapy (IGRT) of TomoDirect for early breast cancer. MATERIALS AND METHODS One hundred and fifty-one breasts of 147 consecutive patients who underwent breast conserving surgery followed by whole breast irradiation using TomoDirect in 2012 and 2013 were evaluated. All patients received weekly IGRT. The w...

متن کامل

Radiobiological Model-Based Comparison of Three-Dimensional Conformal and Intensity-Modulated Radiation Therapy Plans for Nasopharyngeal Carcinoma

Introduction: Radiobiological modeling of radiotherapy plans are used for treatment plan comparisons. The current study aimed to compare the three-dimensional conformal radiation therapy (3DCRT) and intensity-modulated radiation therapy (IMRT) plans for nasopharyngeal cancer using radiobiological modeling. Materials and Methods: This study was conducted on 10 patients with nasopharyngeal carci...

متن کامل

Dosimetric Effects of Rotational Setup Error in Volumetric Modulated Arc Radiotherapy on Brain Tumor Patients

Introduction: This study examined the dosimetric effects based on the rotational setup error to correct patient setup errors occur during volumetric modulated arc radiotherapy (VMAT) for brain tumor patients. Material and Methods: This study included 1129 cases of cone beam computed tomography (CBCT) images obtained from 46 brain tumor patients, who experienced VMAT and used the 6DoF (degree o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2016