Binocular visual simulation of a corneal inlay to increase depth of focus.

نویسندگان

  • Juan Tabernero
  • Christina Schwarz
  • Enrique J Fernández
  • Pablo Artal
چکیده

PURPOSE To investigate binocular visual acuity and depth of focus when one eye forms images through a typical pupil diameter aperture (4 mm) and the other eye through a small pupil of 1.5-mm diameter. METHODS Using a recently developed adaptive optics binocular visual simulator, through focus monocular and binocular visual acuity were measured in three subjects under specially simulated visual conditions: right eyes had "small aperture" vision through a 1.5-mm pupil diameter and left eyes had normal vision through 4-mm pupil diameter. The measurements were performed in photopic and mesopic conditions. RESULTS An increase in binocular and monocular (for the small-aperture eye) depth of focus was measured with respect to the 4-mm pupil diameter eye. It ranged from 1 to 1.5 diopter (D) depending on the threshold requirement and the visibility conditions. For photopic conditions, the J2 visual acuity level was reached at 1 D of defocus for the 4-mm pupil diameter case, while for the 1.5-mm, the J2 level was reached at 2.5 D. Binocular summation occurred only in far vision conditions (no defocus added). For near vision, binocular visual acuity closely followed the values of monocular visual acuity for the eye with the smaller aperture. CONCLUSIONS The small-aperture effect to increase depth of focus in the human eye was successfully implemented in a binocular visual simulator. Although certain limitations exist, the small-aperture approach provided a simple but attractive solution to increase depth of focus in the human eye.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of a hydrogel corneal inlay and monovision laser in situ keratomileusis in presbyopic patients: focus on visual performance and optical quality

PURPOSE To compare the visual performance and optical quality after Raindrop Near Vision Inlay implantation or monovision LASIK for the correction of presbyopia. MATERIALS AND METHODS In this retrospective case-series study, patients previously treated in the nondominant eye with monovision LASIK were compared with patients previously implanted with Raindrop Near Vision Inlay. The study enrol...

متن کامل

Clinical utility of the KAMRA corneal inlay

The treatment of presbyopia has been the focus of much scientific and clinical research over recent years, not least due to an increasingly aging population but also the desire for spectacle independence. Many lens and nonlens-based approaches have been investigated, and with advances in biomaterials and improved surgical methods, removable corneal inlays have been developed. One such developme...

متن کامل

Cataract Surgery with a Refractive Corneal Inlay in Place

Purpose. To present a case of cataract surgery performed in a patient with a refractive corneal inlay in place. Methods. A 48-year-old female patient presented to our institute with bilateral cataract. The patient had undergone refractive corneal inlay implantation three years ago in her right, nondominant eye for presbyopia correction. Biometry and intraocular lens (IOL) power calculation were...

متن کامل

Visual outcomes and safety of a refractive corneal inlay for presbyopia using femtosecond laser.

PURPOSE To evaluate the outcomes and safety of a refractive inlay (Flexivue Micro-Lens, Presbia Coöperatief U.A.) for the corneal compensation of presbyopia. METHODS This prospective, interventional clinical study comprised 47 emmetropic presbyopes with a mean age of 52±4 years (range: 45 to 60 years). The inlay was inserted, centered on the line of sight, inside a corneal pocket created in t...

متن کامل

Long-term outcomes after monocular corneal inlay implantation for the surgical compensation of presbyopia.

PURPOSE To evaluate long-term outcomes of small-aperture corneal inlay implantation for the surgical compensation of presbyopia. SETTING Paracelsus Medical University, Salzburg, Austria. DESIGN Prospective interventional cohort study. METHODS Monocular implantation of a Kamra small-aperture inlay (model ACI7000) (1.6 mm central aperture) was performed in emmetropic presbyopic eyes. The pr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 52 8  شماره 

صفحات  -

تاریخ انتشار 2011