Detailed angiographic analysis of high-speed mechanical rotational atherectomy in human coronary arteries.
نویسندگان
چکیده
BACKGROUND Several types of atherectomy devices have been developed recently for treatment of patients with ischemic heart disease. METHODS AND RESULTS Mechanical rotational atherectomy (MRA) using a high-speed rotational burr (Rotablator) was performed on 116 lesions in 104 patients. MRA alone was performed in 27 lesions (23%), and conventional balloon angioplasty (PTCA) was performed after MRA in 89 lesions (77%). Diameter stenosis decreased from 70 +/- 13% before MRA to 54 +/- 23% after MRA, and the final diameter stenosis (after MRA alone or with adjunctive PTCA) was 30 +/- 20% (P < .001). Minimal lumen diameter increased from 1.0 +/- 0.5 mm before MRA to 1.4 +/- 0.7 mm after MRA, and the final minimal lumen diameter was 2.3 +/- 0.7 mm (P < .001). MRA resulted in a decrease in diameter stenosis of 20% or more in 44% of lesions, and the final diameter stenosis (after MRA alone or after PTCA) was less than 50% in 75% of lesions. Considering the small diameter of available burrs, the magnitude of lumen enlargement was equal to 91% of the burr diameter, and only 9% of the burr diameter was "lost" due to elastic recoil or spasm. These angiographic results were obtained despite the presence of complex lesion morphology, including the presence of calcification in 17% of lesions and ostial location in 26% of lesions. Significant angiographic complications included abrupt closure (13 lesions, 11.2%), no reflow (8 lesions, 7%), severe coronary vasospasm (16 lesions, 13.8%), and guide wire fracture (3 lesions, 2.7%). There were no coronary artery perforations. Adjunctive therapy, including salvage PTCA, thrombolytic agents, and vasodilators, was successful in treating angiographic complications in 42 of 49 lesions (86%). Clinical complications included Q-wave myocardial infarction (5 patients, 4.8%), non-Q-wave myocardial infarction (3 patients, 2.9%), femoral vascular injury requiring surgery (3 patients, 2.9%) or blood transfusion (8 patients, 7.7%), abrupt closure requiring emergency bypass graft surgery (2 patients, 1.9%), and in-hospital death (1 patient, 1.0%). Angiographic follow-up (mean follow-up interval, 5.0 +/- 2.0 months) was available in 84% of successfully treated patients and revealed a restenosis rate of 51%, defined as a residual diameter stenosis of more than 50%. There was no significant difference in restenosis rates between de novo lesions (50%) and restenosis (54%) lesions. CONCLUSIONS These data suggest that for the treatment of most coronary stenoses, PTCA is required after MRA to achieve satisfactory lumen enlargement or to salvage complications. Angiographic complications appear to be more common after MRA, and salvage PTCA often is required to manage these device-induced complications. The combination of MRA and PTCA does not prevent restenosis.
منابع مشابه
Mechanism of high-speed rotational atherectomy and adjunctive balloon angioplasty revisited by quantitative coronary angiography: edge detection versus videodensitometry.
High-speed rotational coronary atherectomy (RA) is primarily used to treat complex lesions. Quantitative angiographic analysis of such complex lesions by edge detection is often unsuitable, whereas videodensitometry, measuring vessel dimensions independently of the target stenosis contours, may offer potential advantages. To gain insight into the operative mechanism of RA and to study the agree...
متن کاملMechanisms of acute lumen gain and recurrent restenosis after rotational atherectomy of diffuse in-stent restenosis: a quantitative angiographic and intravascular ultrasound study.
OBJECTIVES This quantitative angiographic and intravascular ultrasound study determined the mechanisms of acute lumen enlargement and recurrent restenosis after rotational atherectomy (RA) with adjunct percutaneous transluminal coronary angioplasty in the treatment of diffuse in-stent restenosis (ISR). BACKGROUND In-stent restenosis remains a significant clinical problem for which optimal tre...
متن کاملIntravascular ultrasound evaluation of the effect of rotational atherectomy in obstructive atherosclerotic coronary artery disease.
BACKGROUND High-speed rotational atherectomy uses a diamond-coated, elliptical burr to abrade occlusive atherosclerosis, especially noncompliant calcified plaque. METHODS AND RESULTS Intravascular ultrasound (IVUS) was used to analyze 28 patients after atherectomy. Arteries treated and imaged were left main (three), left anterior descending (12), left circumflex (five), right coronary (seven)...
متن کاملDirectional coronary atherectomy vs. rotational atherectomy for the treatment of in-stent restenosis of native coronary arteries.
Management of in-stent restenosis has become a significant challenge in interventional cardiology. Since the mechanism of in-stent restenosis is predominantly intimal hyperplasia, debulking techniques have been used to treat this condition. This study is a nonrandomized comparison of the immediate and long-term results of directional coronary atherectomy (DCA; n = 58) vs. high-speed rotational ...
متن کاملTreatment of In-Stent Restenosis With Excimer Laser Coronary Angioplasty Versus Rotational Atherectomy Comparative Mechanisms and Results
Background—Atheroablation yields improved clinical results for balloon angioplasty (percutaneous transluminal coronary angioplasty, PTCA) in the treatment of diffuse in-stent restenosis (ISR). Methods and Results—We compared the mechanisms and clinical results of excimer laser coronary angioplasty (ELCA) versus rotational atherectomy (RA), both followed by adjunct PTCA; 119 patients (158 ISR le...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 88 3 شماره
صفحات -
تاریخ انتشار 1993