Atrioventricular Conduction in Patients with Incomplete Endocardial Cushion Defect By DANIEL

نویسندگان

  • DONALD C. HARRISON
  • DAVID S. CANNOM
چکیده

The cause of left axis deviation noted on the electrocardiogram (ECG) in patients with ostium primum atrial septal defect has been attributed to two differing mechanisms: left ventricular overload secondary to mitral insufficiency and a congenitally anomalous atrioventricular conduction system. In order to define the conduction characteristics of the atrioventricular conduction system in patients free from the hemodynamic abnormalities of ostium primum atrial septal defect, seven patients with an ostium primum atrial septal defect were studied in the late postoperative period. Each ECG showed persisting left axis deviation with no new conduction abnormalities. Hemodynamic evaluation, including leftventriculography, showed no intra-atrial shunting and only minimal mitral insufficiency in three patients. His bundle recording techniques were utilized to study the atrioventricular conduction system. The P-A interval was normal in four patients (25-45 msec) and prolonged in three (50, 60 and 60 msec), while the A-H interval was normal in all seven patients (60-130 msec). This is compatible with abnormal intra-atrial conduction and normal conduction through the atrioventricular node. The H-V interval was normal in four patients (35-55 msec) and short in three (20, 25, and 25 msec). Atrial pacing produced the normally expected A-H prolongation, P-A and H-V remaining constant. These results and the persisting left axis deviation can be explained on the basis of the known anatomy of the atrioventricular conduction system in patients with ostium primum atrial septal defect. The left axis deviation is most probably related to early activation of the postero-basal left ventricular wall (patients with short H-V) and/or late activation of the antero-lateral left ventricular wall (patients with normal H-V). Hemodynamics are not important in producing these findings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Etiology of Prolongation of the P-R Interval

Conduction time from the region of the sinus node to the region of the atrioventricular (A-V) node was studied during open heart surgery in 13 patients with an endocardial cushion type atrial septal defect, eight patients with a secundum type atrial septal defect, one patient with a sinus venosus type atrial septal defect, and eight patients with an intact atrial septum. Internodal conduction t...

متن کامل

Electrophysiologic Delineation of the Intraventricular His Bundle in Two Patients with Endocardial

Two patients who had an endocardial cushion type of ventricular septal defect underwent electrophysiologic studies for detection of specialized conduction tissue during operative repair. In one patient, with an inferior leftward frontal plane QRS axis on the ECG, we recorded an intraventricular His bundle electrogram anterior and superior to the ventricular septal defect. In the other patient, ...

متن کامل

Etiology of prolongation of the P-R interval in patients with an endocardial cushion defect. Further observations on internodal conduction and the polarity of the retrograde P wave.

Conduction time from the region of the sinus node to the region of the atrioventricular (A-V) node was studied during open heart surgery in 13 patients with an endocardial cushion type atrial septal defect, eight patients with a secundum type atrial septal defect, one patient with a sinus venosus type atrial septal defect, and eight patients with an intact atrial septum. Internodal conduction t...

متن کامل

Electrophysiologic delineation of the intraventricular His bundle in two patients with endocardial cushion type of ventricular septal defect.

Two patients who had an endocardial cushion type of ventricular septal defect underwent electrophysiologic studies for detection of specialized conduction tissue during operative repair. In one patient, with an inferior leftward frontal plane QRS axis on the ECG, we recorded an intraventricular His bundle electrograms from both the anterosuperior and posteroinferior margins of the defect, sugge...

متن کامل

Electrophysiologic Delineation of the Intraventricular

Two patients who had an endocardial cushion type of ventricular septal defect underwent electrophysiologic studies for detection of specialized conduction tissue during operative repair. In one patient, with an inferior leftward frontal plane QRS axis on the ECG, we recorded an intraventricular His bundle electrogram anterior and superior to the ventricular septal defect. In the other patient, ...

متن کامل

Acquired right bundle-branch block and left anterior hemiblock in ostium primum atrial septal defect.

Over a 3-year period of observation, the electrocardiogram in an adult patient with an ostium primum atrial septal defect changed from first-degree atrioventricular block alone to right bundle-branch block and left-axis deviation (left anterior hemiblock) with variable atrioventricular block. Coronary atherosclerosis was excluded by selective coronary arteriography. Although right bundle-branch...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005