Characterization of a lipoprotein common to Legionella species as a urinary broad-spectrum antigen for diagnosis of Legionnaires' disease.
نویسندگان
چکیده
We have previously identified the Legionella 19-kDa peptidoglycan-associated lipoprotein (PAL) as a species-common immunodominant antigen. We describe here for the first time the excretion and detection of the PAL antigen in infected urine specimens, which is useful for the diagnosis of Legionnaires' disease. Rabbit anti-PAL immunoglobulin G (IgG) antibody was produced by immunization with the purified, recombinant PAL of Legionella pneumophila serogroup 1 and used in the PAL antigen capture enzyme-linked immunosorbent assay (ELISA) to detect urinary PAL antigen. A soluble-antigen capture ELISA using rabbit IgG antibodies against Legionella soluble antigens was prepared independently and used as a broad-spectrum standard test to detect soluble antigens of several Legionella species. Urine samples were obtained from guinea pigs experimentally infected with each of L. pneumophila serogroups 1, 3, and 6, and other Legionella species. The absorbance values of the PAL antigen ELISA highly correlated with those of the soluble-antigen ELISA in infected urine samples, with a correlation coefficient of 0.84 (P < 0.01). When applied to 17 infected urine samples and 67 negative controls from guinea pigs, the sensitivity and specificity of the PAL antigen capture ELISA were 88.2 and 95.5%, respectively. Compared to the commercial Biotest enzyme immunoassay, the PAL antigen ELISA was more efficient for detecting pneumophila non-serogroup 1 and nonpneumophila species. None of the 161 control human urine specimens obtained from healthy adults and patients with either non-Legionella pneumonia or urinary tract infections tested positive in the PAL antigen ELISA. The present study shows that the Legionella PAL is a very useful broad-spectrum antigen for urinary diagnostic testing. Moreover, since recombinant PAL antigen can be produced more efficiently than the soluble antigens, the development of a broad-spectrum diagnostic immunoassay based on the detection of the PAL antigen appears to be warranted.
منابع مشابه
Laboratory Diagnosis of Pneumonia by Detection of Urinary Antigen Test of Legionella Pnuemophilia
Background and Aims: Legionnaires’ disease is seen in sporadic and epidemic form. The most prevalent cause is Legionella pnuemophilia (L.pneumophila), which produces a severe disease in vulnerable individuals with a high fatality rate. This study was conducted due to the wide and universal distribution of the Legionnaires’ disease, lack of conventional and accessible diagnostic meth...
متن کاملEvaluation of the Binax and Biotest urinary antigen kits for detection of Legionnaires' disease due to multiple serogroups and species of Legionella.
The Binax and the Biotest urinary antigen kits for the detection of Legionnaires' disease caused by organisms other than Legionella pneumophila were compared by testing 45 urine samples from non-Legionella pneumophila serogroup 1 patients previously positive in a broad-spectrum enzyme-linked immunosorbent assay (ELISA). Eighteen were positive with the Binax kit, and 13 were positive with the Bi...
متن کاملCan we truly rely on the urinary antigen test for the diagnosis? Legionella case report
It is critical to diagnose and treat Legionella pneumonia (LP) immediately after infection because of the associated high mortality. The urine antigen test (UAT) is often used for the diagnosis of LP; however, it cannot detect the serogroups of all Legionella species. A detained medical history and several clinical findings such as liver enzyme elevation and hyponatremia are useful in diagnosis...
متن کاملLegionella as a cause of severe pneumonia.
Legionella pneumophila has been found to be a common cause of community-acquired pneumonia in patients who required intensive care unit (ICU) admission. In many studies, the clinical manifestations for Legionnaires' disease were more severe and the mortality was higher when compared with pneumonias of other etiology. However, this may be due to delay in diagnosis and suboptimal antibiotic thera...
متن کاملIsolation of Legionella Pneumophila Serogroups 1, 8 & 10 (Causative Agents of Legionnaires\' Disease) from Water Sources in Tehran, Iran
In this survey, 187 samples collected from 9 different sources of water in Tehran such as: water coolers, neonates incubators, water bathes (37° C), little pools in parks or squares, cooling towers, hot or cold water taps, were examined for Legionnaires' disease agents. Inoculating water samples on selective and nonselective media resulted in isolation of several strains of gram negative bact...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 41 7 شماره
صفحات -
تاریخ انتشار 2003