The light output and the detection efficiency of the liquid scintillator EJ-309.
نویسندگان
چکیده
The light output response and the neutron and gamma-ray detection efficiency are determined for liquid scintillator EJ-309. The light output function is compared to those of previous studies. Experimental efficiency results are compared to predictions from GEANT4, MCNPX and PENELOPE Monte Carlo simulations. The differences associated with the use of different light output functions are discussed.
منابع مشابه
شبیهسازی تابع پاسخ سوسوزنهای آلی به تابش گاما و نوترون با استفاده از کدهای مونت کارلوی FLUKA،MCNPX و SCINFUL
In organic scintillators, the energy distribution of gamma rays and neutrons is indirectly measured by the pulse height distribution of light output produced through gamma ray and neutron reactions in the detectors. Accurate estimate of the interaction of gamma and neutrons in the detector and produce charged secondary particles and subsequent scintillation light produced in the calculation of ...
متن کاملPreparation of nanocomposite scintillator of ZnS doped with Ag, Cu and AgCu for alpha particle detection
ZnS nanoparticles (NPs) doped with Ag, Cu, and AgCu were synthesized using hydrothermal method in water solution. The NPS are characterized by X-ray diffraction (XRD), energy-dispersive X-ray spectroscopy scanning (EDX), scanning electron microscopy (SEM) and dynamic light scattering (DLS). The produced NPs have approximately hexagonal structure and a cubic zinc blended struc...
متن کاملQuick Lmicroscopic I
Features * Three Outputs. (1) fast output for timing; (2) linear output for pulse height analysis; (3) Neutron gate for counting neutrons or for use in coincidence with the fast or linear output. a Detects neutrons with energies from 0.5 MEV to 40 MEV. * High detection efficiency for fast neutrons with 2000:1 rejection ratio for gamma rays. * Useful with NE 311A Boron loaded liquid scintillator...
متن کاملNeutron generator burst timing measured using a pulse shape discrimination plastic scintillator with silicon photomultiplier readout
An EJ-299-34 plastic scintillator with silicon photomultiplier (SiPM) readout was used to measure the fast neutron output of a pulsed Thermo-Fisher A-325 Deuterium-Tritium sealed tube neutron generator (STNG). The SiPM signals were handled by a prototype digital pulse processing system, based on a free-running analogue to digital converter feeding a digital signal processor (DSP). Pulse shape d...
متن کاملComparison of Two Liquid-Liquid Microextractions for the Detection of Crocin in the Saffron and Biological Samples Using UV- Vis Spectrophotometry
In this work, two approaches based on Dispersive Liquid-Liquid MicroExtraction (DLLME) and Dispersive Liquid-Liquid MicroExtraction based on Solidification of Floating Organic Drop (DLLME-SFO) were compared for the extraction and preconcentration of crocin from saffron and biological samples. Different DLLME and DLLME-SFO parameters influencing the extraction efficiency were studied and opt...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine
دوره 89 شماره
صفحات -
تاریخ انتشار 2014