Delta Reverse Polarity Shoulder Replacement: Single Surgeon Experience with a Minimum 2-Year Follow-up

نویسندگان

  • Shah Jehan
  • Magid Eltayeb
  • Mohammad Muddassir Mahmood Javaid
چکیده

BACKGROUND The delta reverse shoulder replacement system was developed for the treatment of rotator cuff arthropathy so that the deltoid can substitute for the deficient rotator cuff. To evaluate the results of delta reverse shoulder replacement for functional improvement and complications in a consecutive series by a single surgeon over a period of six years with a minimum follow-up of 2 years. METHODS The data were collected retrospectively from electronic theatre records. Over a period of 6 years (2006-2012), 46 cases that fulfilled the inclusion criteria were identified. There were 34 females and 12 males. The average age of patients was 76.2 years (range, 58 to 87 years). A single surgeon performed all procedures using the anterosuperior approach. The mean follow-up time was 49 months (range, 24 to 91 months). All cases had preoperative and postoperative Constant scores. We collected the data on indications, hospital stay, and change in the Constant score, complications, and reoperation rates. RESULTS The main indication for surgery was rotator cuff arthropathy (52.2%), followed by massive rotator cuff tear (28.3%), osteoarthritis (8.7%), fractures (6.5%), and rheumatoid arthritis (4.3%). Also, 65.2% of the cases were referred by general practitioners, 26% of the cases were referred by other consultants, and 8.8% of the cases were already under the care of a shoulder surgeon. The average preoperative Constant score was 23.5 (range, 8 to 59). The average Constant score at the final follow-up was 56 (range, 22 to 83). On average, there was an improvement of 33 points in the Constant score. The improvement in the Constant score was significant (p < 0.001). We observed complications in four patients (8.6%). Three of four patients (6.5%) needed reoperation. The first complication was pulmonary embolism in the early postoperative period. The other complications included dissociation of the glenosphere from the metaglene, deltoid detachment, and stitch abscess. CONCLUSIONS This is a single-surgeon, single-approach series of 46 cases with a minimum follow-up of 2 years. At this stage, the results are encouraging with no cases of loosening, dislocation, or nerve injury.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Midterm Results of the Delta Xtend Reverse Shoulder System: A Five-Year Outcome Study

Background: The purpose of this study was to examine the mid-term functional outcomes, radiographic results,and revision rates of patients treated with the Delta Xtend Reverse Shoulder System for both primary and revisionarthroplasty indications.Methods: A retrospective review was conducted of records for all individuals who underwent a reverse shoulderarthroplasty using the Delta Xtend Reverse...

متن کامل

Total Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry

Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...

متن کامل

The Delta III reverse shoulder replacement for cuff tear arthropathy: a single-centre study of 50 consecutive procedures.

The combination of an irreparable tear of the rotator cuff and destructive arthritis of the shoulder joint may cause severe pain, disability and loss of independence in the aged. Standard anatomical shoulder replacements depend on a functioning rotator cuff, and hence may fail in the presence of tears in the cuff. Many designs of non-anatomical constrained or semi-constrained prostheses have be...

متن کامل

Six-year experience with the Delta III reverse shoulder prosthesis.

PURPOSE To report the clinical and radiographic results and complications of the Delta III reverse prosthesis. METHODS 24 women and 2 men aged 62 to 84 (mean, 75) years underwent total shoulder replacement using the Delta III reverse prosthesis. Patient diagnoses were massive rotator cuff tear (n=20), disabling sequelae of proximal humeral fractures (n=3), and failure of an unconstrained arth...

متن کامل

Reverse Shoulder Arthroplasty is Superior to Hemiarthroplasty for Cuff Tear Arthropathy with Preserved Motion

Background: It is unclear whether hemiarthroplasty (HA) or reverse shoulder arthroplasty (RS) are superior for patientswith cuff tear arthropathy (CTA) and preserved preoperative motion (elevation >90˚).Methods: This was a retrospective, single institution study. Patients who underwent RSA or HA for CTA were included ifthey had preserved preoperative motion with a minimum of 2...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2015