Diagnostic accuracy of coronary angiography using 64-slice computed tomography in coronary artery disease

نویسندگان

  • Fu-Bin Yang
  • Wan-Liang Guo
  • Mao Sheng
  • Ling Sun
  • Yue-Yue Ding
  • Qiu-Qin Xu
  • Ming-Guo Xu
  • Hai-Tao Lv
چکیده

OBJECTIVES To conduct a meta-analysis and investigate the diagnostic value of 64-slice computed tomography (CT) angiography for diagnosing coronary artery disease (CAD) in patients. METHODS A comprehensive literature search from March 2005 to August 2014 was performed on the following databases: Cochrane Library; Medline; EmBase; PubMed; and BioMed Central database. As a reference standard, studies that assessed 64-slice CT angiography in detecting coronary artery stenosis (CAS) with invasive coronary angiography were included. Coronary artery stenosis was defined as ≥50% diameter stenosis. Diagnostic value was determined by pooling sensitivity, specificity, positive likelihood ratio (PLR) and negative likelihood ratio (NLR) values at segment-level analysis. Diagnostic accuracy was undertaken using area under the curve (AUC) value and summary receiver operating characteristic (SROC) curves. Publication bias was examined by Deek's funnel plot asymmetry test. RESULTS Eight studies were included in the analysis, enrolling a total of 579 patients (7,407 segment coronary vessels). At segment-level, pooled sensitivity value was 90% (95% confidence interval [CI]: 83-95%), specificity was 91% (95% CI: 61-98%), PLR value was 9.7 (95% CI: 1.8-53.3), and NLR value was 0.11 (95% CI: 0.05-0.22) for CAS. Optimal cut-off point of sensitivity was 90%, and specificity under the SROC curve was 91%. The AUC value was 0.94. CONCLUSION The 64-slice CT angiography is a reliable tool for detection of CAD when using a cut-off of more than or equal to 50% diameter stenosis in elderly population.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of 64-slice spiral computed tomography angiography in a follow-up evaluation after coronary stent implantation: A Chinese clinical study

Background: This study assessed the application value of 64-slice spiral computed tomography angiography (CTA) in a follow-up evaluation of patients receiving coronary stent implantation. Materials and Methods: A total of 468 patients who underwent percutaneous coronary intervention (PCI) at our hospital between January 2013 and October 2016 were selected for this study. Coronary angiography an...

متن کامل

ارزش تشخیصی -MSCT آنژیوگرافی با تکنولوژی  64 - Sliceدر مقایسه با آنژیوگرافی مرسوم در شناسایی بیماری شریان کرونری

Background: Multislice computed tomography (MSCT) is a noninvasive method of detecting coronary artery disease (CAD). The purpose of the present study was to investigate the accuracy of 64-slice MSCT (64-MSCT) in daily practice, without patient selection. Methods: Sixty-four consecutive suspected CAD patients underwent both 64-MSCT and quantitative coronary angiography (QCA). The CT system The...

متن کامل

Accuracy of MSCT Coronary Angiography with 64 Row CT Scanner—Facing the Facts

Improvements in multislice computed tomography (MSCT) angiography of the coronary vessels have enabled the minimally invasive detection of coronary artery stenoses, while quantitative coronary angiography (QCA) is the accepted reference standard for evaluation thereof. Sixteen-slice MSCT showed promising diagnostic accuracy in detecting coronary artery stenoses haemodynamically and the subseque...

متن کامل

Impact of calcification on diagnostic accuracy of 64-slice spiral computed tomography for detecting coronary artery disease: a single center experience.

BACKGROUND The main aim of our study was to investigate the influence of calcification on the accuracy of 64-slice computed tomography for identification of significant coronary artery disease. METHODS A contrast-enhanced 64-slice computed tomography was performed prior to invasive coronary angiography in 168 consecutive patients with suspected coronary artery disease. All coronary segments 1...

متن کامل

Non-invasive coronary computed tomographic angiography for patients with suspected coronary artery disease: the Coronary Angiography by Computed Tomography with the Use of a Submillimeter resolution (CACTUS) trial.

BACKGROUND Non-invasive coronary angiography by multislice spiral computed tomography (MSCT) is a promising method for the diagnosis of coronary artery disease (CAD). However, the clinical role of this method has not been established for specific patient cohorts. Therefore, the objective of the current prospective, blinded study was to investigate the diagnostic value of coronary MSCT angiograp...

متن کامل

Accuracy of MSCT coronary angiography with 64-slice technology: first experience.

AIMS The aim of our study was to investigate the accuracy of 64-slice computed tomography (CT) for assessing haemodynamically significant stenoses of coronary arteries. METHODS AND RESULTS CT angiography was performed in 67 patients (50 male, 17 female; mean age 60.1+/-10.5 years) with suspected coronary artery disease and compared with invasive coronary angiography. All vessels > or =1.5 mm ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 36  شماره 

صفحات  -

تاریخ انتشار 2015