Measurement of breath-by-breath gas exchange during general anaesthesia.

نویسندگان

  • P C Beatty
  • M J Beech
  • T E Healy
چکیده

We describe a single flow transducer breath-by-breath gas exchange measurement system suitable for use during general anaesthesia. The system uses a Fleisch No. 2 pneumotachograph, a mass spectrometer and a microcomputer to give real-time continuous measurements. Correction for apparent gas exchange attributable to changes in gas stored in the lung (functional residual capacity) is available. The correction assumes no gas exchange of either nitrogen or argon for air-breathing subjects or argon only during anaesthesia, while the inspired concentrations are maintained at atmospheric values. The method has been tested against Douglas bag measurement and compared with results from conventional systems used by other authors. The system measurements show broad agreement with Douglas bag measurements, although the limits of agreement are wide for air-breathing volunteers. The system between-breath variation was typical of breath-by-breath methods in other areas of medical research.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DETECTION AND MEASUREMENT OF ACETONE IN THE BREATH OF DIABETICS BY ION MOBILITY SPECTROMETRY METHOD

Background: The ion mobility spectrometry (IMS) is an analytical technique that is widely used due to its high sensitivity and speed for the detection of ionized molecules in gas phase and under atmospheric pressure. Breath analysis is a new method for obtaining information about person's clinical conditions that is considered by researchers. Human exhaled air contains a variety of components s...

متن کامل

Horses Auto-Recruit Their Lungs by Inspiratory Breath Holding Following Recovery from General Anaesthesia

This study evaluated the breathing pattern and distribution of ventilation in horses prior to and following recovery from general anaesthesia using electrical impedance tomography (EIT). Six horses were anaesthetised for 6 hours in dorsal recumbency. Arterial blood gas and EIT measurements were performed 24 hours before (baseline) and 1, 2, 3, 4, 5 and 6 hours after horses stood following anaes...

متن کامل

Biologically variable ventilation prevents deterioration of gas exchange during prolonged anaesthesia.

We have studied the time course of changes in gas exchange and respiratory mechanics using two different modes of ventilation during 7 h of isoflurane anaesthesia in pigs. One group received conventional control mode ventilation (CV). The other group received biologically variable ventilation (BVV) which simulates the breath-to-breath variation in ventilatory frequency (f) that characterizes no...

متن کامل

An appropriate inspiratory flow pattern can enhance CO2 exchange, facilitating protective ventilation of healthy lungs.

BACKGROUND In acute lung injury, CO2 exchange is enhanced by prolonging the volume-weighted mean time for fresh gas to mix with resident alveolar gas, denoted mean distribution time (MDT), and by increasing the flow rate immediately before inspiratory flow interruption, end-inspiratory flow (EIF). The objective was to study these effects in human subjects without lung disease and to analyse the...

متن کامل

Breath tests and airway gas exchange.

Measuring soluble gas in the exhaled breath is a non-invasive technique used to estimate levels of respiratory, solvent, and metabolic gases. The interpretation of these measurements is based on the assumption that the measured gases exchange in the alveoli. While the respiratory gases have a low blood-solubility and exchange in the alveoli, high blood-soluble gases exchange in the airways. The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 71 2  شماره 

صفحات  -

تاریخ انتشار 1992