Traumatic Dislodgement of Tibial Polyethylene Insert after a High-Flex Posterior-Stabilized Total Knee Replacement

نویسندگان

  • Juan Felix Astoul Bonorino
  • Pablo Ariel Isidoro Slullitel
  • Gonzalo Rodrigo Kido
  • Santiago Bongiovanni
  • Renato Vestri
  • Lisandro Carbó
چکیده

Many pathologic entities can produce a painful total knee replacement (TKR) that may lead to potential prosthetic failure. Polyethylene insert dissociation from the tibial baseplate has been described most frequently after mobile-bearing and cruciate-retaining TKRs. However, only 3 tibial insert dislocations in primary fixed-bearing High-Flex posterior-stabilized TKRs have been reported. We present a new case of tibial insert dislocation in a High-Flex model that shares similarities and differences with the cases reported, facilitating the analysis of the potential causes, which still remain undefined.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of Tibial Insert Slope on Polyethylene Wear and Stress

INTRODUCTION: Both posterior stabilized (PS) and cruciate retaining (CR) total knee replacement systems have demonstrated high rates of survivorship, high clinical knee scores and high patient satisfaction scores for decades. However, CR total knees sometimes exhibit more varied kinematics and a smaller range of motion than similar PS knees. Many factors can cause this, but one important factor...

متن کامل

Nontraumatic tibial polyethylene insert cone fracture in mobile-bearing posterior-stabilized total knee arthroplasty

A 72-year-old male patient underwent mobile-bearing posterior-stabilized total knee arthroplasty for osteoarthritis. He experienced a nontraumatic polyethylene tibial insert cone fracture 27 months after surgery. Scanning electron microscopy of the fracture surface of the tibial insert cone suggested progress of ductile breaking from the posterior toward the anterior of the cone due to repeated...

متن کامل

Symptomatic flexion instability in posterior stabilized primary total knee arthroplasty.

Flexion instability in posterior-stabilized total knee arthroplasty is a relatively uncommon but distinct problem that is often underdiagnosed and may require surgical management. This retrospective study evaluated the authors' management strategy and assessed the results of revision surgery. The authors identified 19 knees that underwent revision for isolated flexion instability after primary ...

متن کامل

High Flexion in Contemporary Total Knee Design: a Precursor of Uhmwpe Damage? a Finite Element Study

The success of total knee arthroplasty has contributed to its widening application to a younger, more active patient population whose daily regimen includes more demanding high flexion activities. Worldwide expansion to Middle Eastern and Asian patient populations, where the attainment of high knee joint flexion is often a cultural requirement, has been steadily increasing in recent years. This...

متن کامل

Visualization of femorotibial contact in total knee arthroplasty using X-ray fluoroscopy.

The purpose of this study was to build a visualization technique of the femorotibial contact in fixed-bearing total knee arthroplasty (TKA) using X-ray fluoroscopy, and to apply this technique to a TKA patient during dynamic motion. In vivo kinametcis of the metallic knee implant was determined using a 2D/3D registration technique, which uses computer assisted design (CAD) model of the implant ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2015  شماره 

صفحات  -

تاریخ انتشار 2015