Identification of risk factors for sub-optimal housing conditions in Australian piggeries: Part 4. Emission factors and study recommendations.
نویسندگان
چکیده
The internal concentrations and emission rates of ammonia (NH3), total bacteria, respirable endotoxins, and inhalable and respirable particles were monitored in 160 piggery buildings in four states of Australia (Queensland, Victoria, Western Australia, and South Australia) between autumn 1997 and autumn 1999. Emissions were calculated for individual buildings as a product of internal concentration and ventilation rate, which were estimated by a carbon dioxide balance method. Relative humidity and temperature were also measured. The overall mean emission rates of NH3, total bacteria, respirable endotoxins, inhalable particles, and respirable particles per 500 kg live weight from Australian piggery buildings were 1442.5 mg h(-1), 82.2 x 10(6) cfu h(-1), 20.1 x 10(3) EU h(-1), 1306.7 mg h(-1), and 254.7 mg h(-1), respectively. Internal concentrations of key airborne pollutants have been reported in companion articles. Building characteristics and management systems used in the piggeries were documented at the time of sampling and used in the subsequent statistical modeling of variations in pollutant emission rates. The emissions model used all statistically significant factors identified during prior modeling conducted for individual pollutant concentrations and ventilation airflow. The identification of highly significant factors affecting emission rates and internal concentrations should aid the development of strategies for the industry to reduce emission rates from individual buildings, thus improving the environmental performance of piggery operations. In the second part of the article, specific recommendations are made based on the overall study results.
منابع مشابه
Identification of risk factors for sub-optimal housing conditions in Australian piggeries: Part 1. Study justification and design.
We undertook a literature search related to pig production facilities with two major aims: first, to review all the likely benefits that might be gained from air quality improvements; and second, to review previous research that had identified statistically significant factors affecting airborne pollutants and environmental parameters, so that these factors could be considered in a multifactori...
متن کاملIdentification of risk factors for sub-optimal housing conditions in Australian piggeries: Part 3. Environmental parameters.
Between autumn 1997 and autumn 1999, we measured ventilation rates (using a CO2 balance method), air temperatures, and relative humidity (using self-contained dataloggers with built-in sensors) in 160 pig housing facilities in Queensland, South Australia, Victoria, and Western Australia, in each case over a 60 h period. In some buildings, the internal air velocities above the animals were also ...
متن کاملIdentification of risk factors for sub-optimal housing conditions in Australian piggeries: Part 2. Airborne pollutants.
The concentrations of total airborne bacteria, respirable endotoxins, ammonia, and respirable and inhalable particles were monitored in 160 piggery buildings in Australia between autumn 1997 and autumn 1999. The overall mean airborne bacteria, respirable endotoxins, ammonia (NH3), and inhalable and respirable particle concentrations measured were 1.17 x 10(5) cfu m(-3), 33.1 EU m(-3), 3.7 ppm, ...
متن کاملIdentification and analysis of housing submarkets in Tehran City
Housing Submarkets are a set of dwellings that have similar characteristics. They are reasonably close substitutes for one another, yet relatively poor substitutes for dwelling in other submarkets. Identifying housing sub-markets makes it possible to predict housing prices more accurately. Moreover, it helps planners and policy-makers to make better decisions. Despite the importance of this iss...
متن کاملA comparative study of the effect of physical-social factors on the quality of life of residents of different types of housing in quarantine conditions (Case study: different types of housing in Tehran).
Abstract: The concept of quality of life consists of concepts such as "return" which focuses on the personal aspect to "good place" which focuses on the situation. Housing,as a basic human need and a provider of his sense of satisfaction, plays an essential role in improving the quality of life.Emphasis on industrialization and the presentation of non-indigenous housing patterns in the country...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of agricultural safety and health
دوره 14 1 شماره
صفحات -
تاریخ انتشار 2008