Improvement of Input Power Factor in PWM AC Chopper by Selecting the Optimal Parameters

نویسنده

  • Wanchai KHAMSEN
چکیده

A technique for selecting the element values of the PWM AC chopper circuits to improve the input power factor is presented. This technique analyzes the phase angles of input current, output current and voltage for selecting the optimal value of the filter capacitance. This produces the phase angle of input current in phase with that of input voltage. Therefore, the PWM AC chopper can operate at unity input power factor. The simulation by PSpice program and experimental results are used to verify the proposed technique. Streszczenie. Zaprezentowano metodę selekcji elementów choppera PWM AC w celu poprawy wejściowego współczynnika mocy. Metoda polega na analizie kąta fazowego prądu wejściowego, prądu wyjściowego i napięcia w celu optymalizacji pojemności filtru. Dzięki temu chopper pracuje przy współczynniku mocy równym 1. (Optymalny dobór elementów choppera PWM AC w celu poprawy wejściowego współczynnika mocy)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Novel Dynamic Voltage Regulator with a Multi-level AC/AC Converter

This article proposed a novel topology of dynamic voltage regulator using transformer and PWM multi-level AC/AC converter. In this paper for finding the best value of duty ratio for switches to minimize the THD, the GA algorithm has been used and THD output voltage is assumed to be fitness function. The proposed voltage regulator employs multi-level AC/AC converter to generate compensation volt...

متن کامل

Improving Voltage Regulation and Elimination of Harmonics in Pwm Ac Chopper Using Artificial Intelligent Technique

This paper proposes a harmonic reduction approach and output voltage regulation in pulse width modulation (PWM) based AC Chopper using artificial intelligent technique. The optimal switching angles are provided by artificial intelligent technique to minimize harmonic distortions. In addition, the simulation results are correlated to confirm the performance in terms of power factor by improving ...

متن کامل

Voltage Quality Improvement Using AC-Chopper in Distribution Line

Voltage sag is an important power quality problem, which may affect domestic, industrial and commercial customers. Voltage sags may either decrease or increase in the magnitude of system voltage due to faults or change in loads. Momentary and sustained over voltage and under voltage ma y cause the equipment to trip out, which is highly undesirable in certain application. In order to maintain th...

متن کامل

Universal motor speed control with current controlled PWM AC chopper by using a microcontroller

In this paper, universal motor speed control system with a PWM AC chopper is introduced. Operation principles of the control system, which is realized with a microcontroller, are presented. Mathematical model of the universal motor and PWM AC chopper is derived and the behavior of the system is studied by simulation. Mains power factor, motor speed, and current are analyzed for different load c...

متن کامل

Power Factor Improvement and Harmonic Current Reduction in Dual Feedback Pwm Controlled Ac/dc Drives

The electrical power industry has grown rapidly and loads are changing from simple, non-electronic loads to electronic ones. These electronic loads draw a non-sinusoidal current even when the supply voltage is perfectly sinusoidal. In this paper PWM controller with dual feedback loop with simple single-stage single-switch input-current shaping circuit was designed, simulated and tested for AC/D...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013