Development and validation of a standardized method for contouring the brachial plexus: preliminary dosimetric analysis among patients treated with IMRT for head-and-neck cancer.
نویسندگان
چکیده
PURPOSE Although Radiation Therapy Oncology Group protocols have proposed a limiting dose to the brachial plexus for patients undergoing intensity-modulated radiotherapy for head-and-neck cancer, essentially no recommendations exist for the delineation of this structure for treatment planning. METHODS AND MATERIALS Using anatomic texts, radiologic data, and magnetic resonance imaging, a standardized method for delineating the brachial plexus on 3-mm axial computed tomography images was devised. A neuroradiologist assisted with identification of the brachial plexus and adjacent structures. This organ at risk was then contoured on 10 consecutive patients undergoing intensity-modulated radiotherapy for head-and-neck cancer. Dose-volume histogram curves were generated by applying the proposed brachial plexus contour to the initial treatment plan. RESULTS The total dose to the planning target volume ranged from 60 to 70 Gy (median, 70). The mean brachial plexus volume was 33 +/- 4 cm(3) (range, 25.1-39.4). The mean irradiated volumes of the brachial plexus were 50 Gy (17 +/- 3 cm(3)), 60 Gy (6 +/- 3 cm(3)), 66 Gy (2 +/- 1 cm(3)), 70 Gy (0 +/- 1 cm(3)). The maximal dose to the brachial plexus was 69.9 Gy (range, 62.3-76.9) and was >/=60 Gy, >/=66 Gy, and >/=70 Gy in 100%, 70%, and 30% of patients, respectively. CONCLUSIONS This technique provides a precise and accurate method for delineating the brachial plexus organ at risk on treatment planning computed tomography scans. Our dosimetric analysis suggest that for patients undergoing intensity-modulated radiotherapy for head-and-neck cancer, brachial plexus routinely receives doses in excess of historic and Radiation Therapy Oncology Group limits.
منابع مشابه
Using overlap volume histogram and IMRT plan data to guide and automate VMAT planning: a head-and-neck case study.
PURPOSE To investigate whether an overlap volume histogram (OVH)-driven planning application using an intensity-modulated radiation therapy (IMRT) database can guide and automate volumetric-modulated arc therapy (VMAT) planning for head-and-neck cancer. METHODS Based on comparable head-and-neck dosimetric results between planner-generated VMAT and IMRT plans, an inhouse developed, OVH-driven ...
متن کاملIntensity-modulated radiotherapy increases dose to the brachial plexus compared with conventional radiotherapy for head and neck cancer.
OBJECTIVE The preferential use of intensity-modulated radiotherapy (IMRT) over conventional radiotherapy (CRT) in the treatment of head and neck cancer has raised concerns regarding dose to non-target tissue. The purpose of this study was to compare dose-volume characteristics with the brachial plexus between treatment plans generated by IMRT and CRT using several common treatment scenarios. ...
متن کاملSchwannoma of the Brachial Plexus: A Rare Case Report
Introduction: Brachial plexus schwannomas are extremely rare tumours of the head and neck region accounting for less than 5 % overall. Due to its rarity and anatomic complexity of the brachial plexus, schwannomas in this region present a diagnostic and surgical challenge to the surgeon. Case Report: We present a case of a 56-year-old female who presented with a slow gr...
متن کاملDose Distribution Analysis of Rapid Arc and Intensity Modulated Radiotherapy Plan in Head and Neck Cancer
Introduction: Globally, intensity-modulated radiation therapy (IMRT) is considered as highly precise and accurate method of radiotherapy planning. This technique amplifies spatial dose distribution conformity by modulating the intensity of radiation beams in each sub-volume. Additionally, it can reduces the dose to surrounding critical organs and deliver the planned dose to targets with the nom...
متن کاملAssessment of shoulder position variation and its impact on IMRT and VMAT doses for head and neck cancer
BACKGROUND For radiotherapy of the head and neck, 5-point mask immobilization is used to stabilize the shoulders. Still, the daily position of the shoulders during treatment may be different from the position in the treatment plan despite correct isocenter setup. The purpose of this study was to determine the interfractional displacement of the shoulders relative to isocenter over the course of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of radiation oncology, biology, physics
دوره 72 5 شماره
صفحات -
تاریخ انتشار 2008