Dry-reagent double-monoclonal assay for cystatin C.
نویسندگان
چکیده
BACKGROUND Cystatin C is a low molecular weight cysteine proteinase inhibitor whose plasma or serum concentrations have been shown to be better correlated with glomerular filtration rate than serum creatinine concentrations. Routine assays for cystatin C are based on use of polyclonal antibodies and immunoturbidimetric and nephelometric designs. This study aimed to develop a double-monoclonal immunoassay for cystatin C. METHODS We tested functionality of 42 2-site antibody combinations involving 7 monoclonal antibodies with recombinant and plasma cystatin C. We developed a heterogeneous assay using 2 antibodies selected to give the best analytical performance. The assay used a dilution step and was based on a dry-reagent, all-in-one immunoassay concept with time-resolved fluorometry. The assay was performed on an automated immunoanalyzer in single wells that contained all the required assay components. We used heparin-derived plasma samples for methodological evaluation of the assay. RESULTS From a relative epitope map involving 7 cystatin C-specific antibodies, we selected a pair of antibodies for a 2-site sandwich-type dry-reagent assay. Total assay time was 15 min, and 10 microL of a 100-fold diluted sample was used. The analytical detection limit (background + 3SD) and functional detection limit (CV 20%) were 0.01 mg/L and 0.02 mg/L, respectively. Within-run and total assay imprecision were <4.7% and <5.6% (at 0.84-3.2 mg/L), respectively, and plasma recoveries of added cystatin C were 94%-110%. Regression analysis with the Roche particle-enhanced immunoturbidimetric method yielded the following (SD): slope, 1.391 (0.029); y-intercept, -0.152 (0.045) mg/L; S(y logical or, bar belowx)=0.294 mg/L (n=131). CONCLUSIONS The developed assay enables rapid and reliable measurement of cystatin C.
منابع مشابه
Evaluation of a new immunoassay for cystatin C, based on a double monoclonal principle, in men with normal and impaired renal function
BACKGROUND Elevated cystatin C in blood reflects impaired glomerular filtration rate (GFR), but current cystatin C assays, based on polyclonal antibodies and immunoturbidimetric or nephelometric detection, have several limitations. We evaluated a new immunoassay based on monoclonal antibodies in samples from patients with and without chronic kidney disease (CKD). METHODS The study enrolled 17...
متن کاملDiagnosis of schistosomiasis by reagent strip test for detection of circulating cathodic antigen.
A newly developed reagent strip assay for the diagnosis of schistosomiasis based on parasite antigen detection in urine of infected individuals was evaluated. The test uses the principle of lateral flow through a nitrocellulose strip of the sample mixed with a colloidal carbon conjugate of a monoclonal antibody specific for Schistosoma circulating cathodic antigen (CCA). The strip assay to diag...
متن کاملDiagnosis of cerebral amyloid angiopathy by enzyme-linked immunosorbent assay of cystatin C in cerebrospinal fluid.
An abnormally low level of cystatin C in the cerebrospinal fluid is a diagnostic marker for the hereditary form of brain hemorrhage associated with amyloidosis that was first identified in Iceland. We developed an assay for cystatin C to use in the diagnosis of patients with cerebral amyloid angiopathy and brain hemorrhage. This test consists of a sandwich enzyme-linked immunosorbent assay usin...
متن کاملSERUM CYSTATIN C AS A NEW MARKER OF GLOMERULAR FILTRATION RATE (GFR)
Cystatin C is a 13 KD basic protein that is a member of the cystatin superfamily of cysteine protease inhibitors. The cystatin C gene seems to be a house keeping gene, which is compatible with a stable production rate of cystatin C by most cells. This protein is freely filtered through the glomerulus and almost completely reabsorbed and catabolized by proximal tubular cells. Because of the...
متن کاملRapid diagnosis of schistosomiasis by antigen detection in urine with a reagent strip.
For the rapid and simple diagnosis of schistosomiasis, a reagent strip assay for detection of circulating cathodic antigen (CCA) in urine was developed. The test was based on a previously developed sandwich enzyme-linked immunosorbent assay (ELISA) using a combination of two anti-CCA monoclonal antibodies. For the reagent strip assay, as the capture matrix, monoclonal antibody was coated onto a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 56 9 شماره
صفحات -
تاریخ انتشار 2010