Influence of coronary flow profiles on bolus shape and quantitative myocardial perfusion MRI

نویسندگان

  • Dirk Graafen
  • Julia Hamer
  • Regine Schmidt
  • Melanie Schmitt
  • Stefan Weber
  • Laura M Schreiber
چکیده

Simulations of the influence of contrast agent bolus dispersion on the shape of the contrast agent bolus and on quantification of myocardial blood flow (MBF) have been made using an exponential residue function model, and an computational fluid dynamics (CFD) approach. Based on the exponential residue function model, up to 20% underestimation of MBF appeared reasonable. CFD simulations showed that bolus dispersion occures in normal coronary vessels as well as in those with stenosis. However, bolus dispersion was smaller with stenosis than without.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Computational Fluid Dynamics Simulations of Contrast Agent Bolus Dispersion in a Coronary Bifurcation: Impact on MRI-Based Quantification of Myocardial Perfusion

Contrast-enhanced first-pass magnetic resonance imaging (MRI) in combination with a tracer kinetic model, for example, MMID4, can be used to determine myocardial blood flow (MBF) and myocardial perfusion reserve (MPR). Typically, the arterial input function (AIF) required for this methodology is estimated from the left ventricle (LV). Dispersion of the contrast agent bolus might occur between t...

متن کامل

Nicorandil effect on myocardial perfusion in patients with slow coronary flow phenomenon assessment by gated myocardial perfusion SPECT

Introduction:Patients with the coronary slow flow phenomenon (SCF) frequently experience angina episodes. The purpose of this study was to determine efficacy of nicorandil in myocardial perfusion in patients with SCF. Methods: Twenty patients (50.85 ± 12.96 y) with SCF were studied.  We evaluate coronary slow flow according to protracted thrombolysis in m...

متن کامل

Estimation of absolute myocardial blood flow during first-pass MR perfusion imaging using a dual-bolus injection technique: comparison to single-bolus injection method.

PURPOSE To compare the dual-bolus to single-bolus quantitative first-pass magnetic resonance myocardial perfusion imaging for estimation of absolute myocardial blood flow (MBF). MATERIALS AND METHODS Dogs had local hyperemia of MBF in the left anterior descending (LAD) coronary artery (intracoronary adenosine). Animals (n = 6) had sequential single- and dual-bolus perfusion studies with micro...

متن کامل

Quantitative Myocardial Perfusion Using Conventional Single-Bolus Contrast Imaging Overestimates Absolute Myocardial Blood Flow Compared with Dual-Bolus or Dual-Sequence Cardiac MR Methods

Introduction: Estimates of myocardial blood flow (MBF) from first-pass contrast-enhanced cardiac magnetic resonance (CMR) imaging require accurate measurement of the arterial input function (AIF) from the left-ventricular (LV) blood pool. Both dual-bolus [1] and dual-sequence [2,3] CMR methods have been proposed to maintain the linearity of the LV signal during the contrast passage. Several stu...

متن کامل

Quantitative Contrast-Enhanced Myocardial Perfusion MRI: Simulation of Bolus Dispersion in Constricted Vessels

Introduction Quantification of myocardial blood flow by means of dynamic T1-weigthed MRI requires the knowledge of the arterial input function (AIF). In first pass myocardial perfusion imaging the AIF is usually estimated from the left ventricle (LV) [1-3]. Dispersion of the contrast agent bolus may occur between the LV and the tissue of interest, e.g. as a result of the vascular flow profile, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2012