Psychometric properties of the Greek version of the NEI-VFQ 25

نویسندگان

  • Georgios Labiris
  • Andreas Katsanos
  • Michael Fanariotis
  • Theodora Tsirouki
  • Maria Pefkianaki
  • Dimitrios Chatzoulis
  • Evangelia Tsironi
چکیده

BACKGROUND To evaluate the reliability and construct validity of a Greek version of the NEI-VFQ-25 in patients with chronic ophthalmic diseases. METHODS We developed the Greek version of the instrument using forward and backward translation. One hundred-eighty-six patients responded to the questionnaire. To examine reliability, Cronbach's alpha for each subscale was used as an index of internal consistency. Test-retest reliability was evaluated with intraclass correlation coefficients. Regarding construct validity, both convergent and discriminant validities were calculated by means of multi-trait analysis. Rasch analysis was used to estimate the visual ability required by each item for a particular response, and each patient's visual ability. Correspondingly, instrument validity was evaluated by estimating the distribution of residuals for item and subject measures. RESULTS Four patient groups were studied, each including participants with a single cause of visual impairment. Group 1 consisted of 84 glaucoma subjects. Group 2 included 30 subjects with age-related macular degeneration (ARMD); group 3 included 25 subjects with dry-eye syndrome, whereas group 4 included 18 cataract patients. Twenty-nine healthy individuals comprised the control group. NEI-VFQ scores (mean +/- SD) for the glaucoma, ARMD, dry-eye, cataract and control groups were: 76.9 +/- 20.2, 70.9 +/- 20.2, 81.6 +/- 16.5, 73.5 +/- 24.0 and 93.7 +/- 8.9 respectively. Item analysis revealed no significant data skewing. Cronbach's alpha ranged from 0.678 to 0.926, with most subscales having high internal consistency. Intraclass correlation coefficient ranged from 0.717 to 0.910 for all subscales. All items passed the convergent and discriminant validity tests. Strong correlations were detected between visual acuity and "general vision", "distant activities" and "near activities" subscales. Significant correlations were also detected between visual field deficits and the "peripheral vision" and "general vision" subscales. Rasch analysis revealed potential weaknesses of the instrument that are associated with the assumptions of the model itself. Specifically, low precision of the "agreement" items was detected in the estimation of visual ability. Twenty-three percent of the subjects had fit statistics that fell outside the tolerance box. CONCLUSION Although traditional validation methods indicated that the Greek version of the NEI-VFQ-25 is a valid and reliable instrument for VS-QoL assessment, Rasch analysis detected significant misfits to the model, especially of the "agreement" items. This means that results of the corresponding subscales should be interpreted with extreme caution.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of the 25-item National Eye Institute Visual Function Questionnaire.

OBJECTIVE To develop and test the psychometric properties of a 25-item version of the National Eye Institute Visual Function Questionnaire (NEI VFQ-25). DESIGN Prospective observational cohort study of persons with 1 of 5 chronic eye diseases or low vision who were scheduled for nonurgent visits in ophthalmology practices and a reference sample of persons without eye disease. SETTING Eleven...

متن کامل

Remediating serious flaws in the National Eye Institute Visual Function Questionnaire.

PURPOSE To test the assumption that the National Eye Institute Visual Function Questionnaire (NEI VFQ) measures visual functioning, assess the validity of its subscales, and, if flawed, revise the questionnaire and derive a shortened version with sound psychometric properties. SETTING Flinders Medical Centre, Adelaide, Australia. METHODS Patients from the cataract surgery waiting list self-...

متن کامل

Development of a new Rasch-based scoring algorithm for the National Eye Institute Visual Functioning Questionnaire to improve its interpretability

BACKGROUND The NEI VFQ-25 has undergone psychometric evaluation in patients with varying ocular conditions and the general population. However, important limitations which may affect the interpretation of clinical trial results have been previously identified, such as concerns with reliability and validity. The purpose of this study was to evaluate the National Eye Institute Visual Functioning ...

متن کامل

The psychometric validity of the NEI VFQ-25 for use in a low-vision population.

PURPOSE To determine the psychometric validity of the National Eye Institute-Visual Function Questionnaire (NEI VFQ-25) and its subscale structure for use in people with low vision. METHODS Two hundred thirty-two participants completed the NEI VFQ-25. Rasch analysis was used to test the psychometric performance of the questionnaire and each subscale. Factor models were hypothesized and tested...

متن کامل

Psychometric performance of the NEI VFQ-25 in visually normal Latinos: the Los Angeles Latino Eye Study.

PURPOSE To characterize the psychometric performance of the National Eye Institute 25-item Visual Function Questionnaire (NEI VFQ-25) in visually normal Latinos (Mexican Americans). METHODS The Los Angeles Latino Eye Study (LALES) is a population-based study to assess the prevalence of eye disease and self-reported visual functioning in Latinos aged 40 or more years. Self-reported visual func...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • BMC Ophthalmology

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2008