Characterization of the excitable gap in a functionally determined reentrant circuit. Studies in the sterile pericarditis model of atrial flutter.

نویسندگان

  • S Niwano
  • J Ortiz
  • H Abe
  • X Gonzalez
  • Y Rudy
  • A L Waldo
چکیده

BACKGROUND Single premature beats were introduced in the reentrant circuit during stable atrial flutter in the canine sterile pericarditis model to test the hypotheses that (1) despite the fact that the reentrant circuit is functionally determined, there is a fully excitable gap; (2) the excitable gap in the reentrant circuit is not uniform; and (3) inhomogeneities of conduction in the reentrant circuit explain the effects of premature beats. METHODS AND RESULTS A multiplexing system was used to record 190 unipolar electrograms from the right atrial free wall during 18 atrial flutter episodes in 9 dogs. In all 18 episodes, premature stimuli captured the atrial flutter reentrant circuit. At the longest coupling intervals, the return cycle at the site closest to the pacing site did not prolong. As the coupling interval of the premature stimulus decreased, the return cycle then progressively increased, associated with changes in conduction in the reentrant circuit that were not uniform. The result was that coupling intervals associated with introduction of the premature beat also were not constant. The mean duration of the total (ie, fully plus partially) excitable gap was 12 +/- 4 ms in areas of slow conduction, and it was always shorter than the total excitable gap in other areas (22 +/- 6 ms, P < .001). The mean duration of the fully excitable gap based on analysis of the return cycle was 4 +/- 1 ms in the reentrant circuit. In 13 of 18 atrial flutter episodes, a premature stimulus terminated atrial flutter by causing block of the orthodromic wave front of the premature beat in an area of slow conduction. The mean coupling interval that caused orthodromic block was 113 +/- 5 ms (recorded at the site just proximal to the area of block), and it was always longer than the delivered stimulus coupling interval at the pacing site (96 +/- 8 ms, P < .001). CONCLUSIONS We conclude that in this functionally determined atrial flutter reentrant circuit in the canine sterile pericarditis model, (1) a fully excitable gap is present in at least part of the reentrant circuit; (2) the duration of the excitable gap in the reentrant circuit is shortest in areas of slow conduction; and (3) when a premature beat encounters the partially excitable gap of the reentrant circuit, it results in changes in conduction such that the coupling intervals are not uniform throughout in the reentrant circuit.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Circus movement atrial flutter in the canine sterile pericarditis model. Differential effects of procainamide on the components of the reentrant pathway.

To evaluate the mechanisms of action of procainamide on the components of the reentrant pathway, drug-induced changes in activation patterns, effective refractory periods (ERPs), and stimulation thresholds were analyzed in nine dogs with sterile pericarditis and sustained atrial flutter. Activation maps were based on 127 close bipolar recordings from a special "jacket" electrode. From the contr...

متن کامل

New insights regarding the atrial flutter reentrant circuit : studies in the canine sterile pericarditis model.

Background-We studied atrial activation during induced atrial flutter in the canine sterile pericarditis model to test the hypothesis that the atrial flutter reentrant circuit includes a septal component. Methods and Results-We studied 10 episodes of induced, sustained (>5 minutes) atrial flutter in 9 dogs. In all episodes, the reentrant circuit included a septal component. In 6 episodes, there...

متن کامل

Mechanism of spontaneous termination of stable atrial flutter in the canine sterile pericarditis model.

BACKGROUND We tested the hypotheses that spontaneous termination of stable atrial flutter is directly related to spontaneous beat-to-beat cycle length oscillations and that block of the circulating reentrant wave front occurs in an area of slow conduction. METHODS AND RESULTS We studied 30 episodes of spontaneous termination of stable atrial flutter induced by atrial stimulation in 11 conscio...

متن کامل

Mechanism of interruption of atrial flutter by moricizine. Electrophysiological and multiplexing studies in the canine sterile pericarditis model of atrial flutter.

BACKGROUND Moricizine is said to have potent effects on cardiac conduction but little or no effect on cardiac refractoriness. METHODS AND RESULTS The effects of moricizine (2 mg/kg IV) on induced atrial flutter were studied 2 to 4 days after the creation of sterile pericarditis in 11 dogs. Ten episodes of stable atrial flutter before and after the administration of moricizine were studied in ...

متن کامل

Circus movement atrial flutter in canine sterile pericarditis model. Activation patterns during entrainment and termination of single-loop reentry in vivo.

BACKGROUND Recently, we used a custom designed "jacket" electrode with 127 bipolar electrodes in a flexible nylon matrix to map the total atrial epicardial surface in the in situ canine heart. Atrial flutter in dogs with sterile pericarditis was shown to be due to a single wave front circulating around a combined functional/anatomic obstacle, with the arc of functional conduction block contiguo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 90 4  شماره 

صفحات  -

تاریخ انتشار 1994