Validation, repeatability and reproducibility of a noninvasive instrument for measuring thoracic and lumbar curvature of the spine in the sagittal plane.

نویسندگان

  • Fabiana O Chaise
  • Cláudia T Candotti
  • Marcelo L Torre
  • Tássia S Furlanetto
  • Patricia P T Pelinson
  • Jefferson F Loss
چکیده

BACKGROUND The need for early identification of postural abnormalities without exposing patients to constant radiation has stimulated the development of instruments aiming to measure the spinal curvatures. OBJECTIVE To verify the validity, repeatability and reproducibility of angular measures of sagittal curvatures of the spine obtained using an adapted arcometer, by comparing them with Cobb angles of the respective curvatures obtained by using X-rays. METHODS 52 participants were submitted to two procedures designed to evaluate the thoracic and lumbar curvatures: (1) X-ray examination from which the Cobb angles (CA) of both curvatures were obtained, and (2) measuring the angles with the arcometer (AA). Two evaluators collected the data using the arcometer, with the rods placed at T1, T12, L1 and L5 spinous processes levels in a way as to permit linear measurements which, with aid of trigonometry, supplied the AA. RESULTS There was a very strong and significant correlation between AA and CA (r=0.94; p<0.01), with no-significant difference (p=0.32), for the thoracic curvature. There was a strong and significant correlation for the lumbar curvature (r=0.71; p<0.01) between AA and CA, with no-significant difference (p=0.30). There is a very strong correlation between intra-evaluator and inter-evaluator AA. CONCLUSION It was possible to quantify reliably the thoracic and lumbar curvatures with the arcometer and it can thus be considered valid and reliable and for use in evaluating spinal curvatures in the sagittal plane.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of the human spine curve based on laser triangulation

BACKGROUND The main objective of the present method was to automatically obtain a spatial curve of the thoracic and lumbar spine based on a 3D shape measurement of a human torso with developed scoliosis. Manual determination of the spine curve, which was based on palpation of the thoracic and lumbar spinous processes, was found to be an appropriate way to validate the method. Therefore a new, n...

متن کامل

Reproducibility of kinematic measures of the thoracic spine, lumbar spine and pelvis during fast running.

This study evaluated the reproducibility of the angular rotations of the thoracic spine, lumbar spine, pelvis and lower extremity during running. In addition, the study compared kinematic reproducibility between two methods for calculating kinematic trajectories: a six degrees of freedom (6DOF) approach and a global optimisation (GO) approach. With the first approach segments were treated indep...

متن کامل

Can the adapted arcometer be used to assess the vertebral column in children?

BACKGROUND The adapted arcometer has been validated for use in adults. However, its suitability for use in children can be questioned given the structural differences present in these populations. OBJECTIVE To verify the concurrent validity, repeatability, and intra- and inter-reproducibility of the adapted arcometer for the measurement of the angles of thoracic kyphosis and lumbar lordosis i...

متن کامل

Validity and Reproducibility of the Measurements Obtained Using the Flexicurve Instrument to Evaluate the Angles of Thoracic and Lumbar Curvatures of the Spine in the Sagittal Plane

Objective. to verify the validity and reproducibility of using the flexicurve to measure the angles of the thoracic and lumbar curvatures. Method. 47 subjects were evaluated by: (1) palpation and marking of the spinous processes using lead markers, (2) using X-rays in the sagittal plane to measure the Cobb angles, (3) molding the flexicurve to the spine, and (4) drawing the contour of the flexi...

متن کامل

Comparison between the effects of Harrington Rod and multisegmented instrumentations in sagittal plane correction of idiopathic scoliosis

 Abstract Objective: To present the changes in projected thoracic hypokyphosis and the behavior of lumbar lordosis within and below the fusion and to compare these changes between the Harrington rod (HR) and posterior multisegmented hook instrumentation. Methods: 178 patients with idiopathic scoliosis, who had undergone posterior spinal fusion with Harrington technique (106 patients) or multise...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Revista brasileira de fisioterapia (Sao Carlos (Sao Paulo, Brazil))

دوره 15 6  شماره 

صفحات  -

تاریخ انتشار 2011