An experimental evaluation of the structural health monitoring capability of piezoelectric wafer active sensors on composite structures at cryogenic temperatures is presented. The piezoelectric wafer active sensor–based electromechanical impedance and the pitch–catch methods were first qualified for cryogenic temperatures using piezoelectric wafer active sensor–instrumented composite specimens dipped in liquid N2. Subsequently, damage detection experiments were performed on laboratory-scale composite specimens with (a) impact damage and (b) built-in Teflon patches simulating in service delaminations. Finally, a comprehensive damage detection test was performed on a full-scale specimen subjected to pressure and cryogenic temperature cycles. Based on these tests, we conclude that piezoelectric wafer active sensor–based structural health monitoring methods show promise for damage detection in composite materials even in extreme cryogenic conditions. Recommendations for further work are also included.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Pitch-Catch Based Online Structural Health Monitoring of Pressure Vessels, Considering Corrosion Formation

Structural health monitoring is a developing research field which is multifunctional and can estimate the health condition of the structure by data analyzing and also can prognosticate the structural damages. Illuminating the damages by using piezoelectric sensors is one of the most effective techniques in structural health monitoring. Pressurized equipments are very important components in pro...

متن کامل

Damage detection and structural health monitoring of ST-37 plate using smart materials and signal processing by artificial neural networks

Structural health monitoring (SHM) systems operate online and test different materials using ultrasonic guided waves and piezoelectric smart materials. These systems are permanently installed on the structures and display information on the monitor screen. The user informs the engineers of the existing damage after observing signal loss which appears after damage is caused. In this paper health...

متن کامل

Thermo-Electro Mechanical Impedance based Structural Health Monitoring: Euler- Bernoulli Beam Modeling

In recent years, impedance measurement method by piezoelectric (PZT) wafer activesensor (PWAS) has been widely adopted for non-destructive evaluation (NDE). In this method, theelectrical impedance of a bonded PWAS is used to detect a structural defect. The electro-mechanicalcoupling of PZT materials constructs the original principle of this method. Accordingly, the electricalimpedance of PWAS c...

متن کامل

Feature Selection in Structural Health Monitoring Big Data Using a Meta-Heuristic Optimization Algorithm

This paper focuses on the processing of structural health monitoring (SHM) big data. Extracted features of a  structure are reduced using an optimization algorithm to find a minimal subset of salient features by removing noisy, irrelevant and redundant data. The PSO-Harmony algorithm is introduced for feature selection to enhance the capability of the proposed method for processing the  measure...

متن کامل

Health Monitoring of Welded Steel Pipes by Vibration Analysis

In the present work, structure health monitoring (SHM) of welded steel pipes was used to diagnosis their state via vibration based damage detection techniques. The dynamic quantities such as Frequency Response Functions (FRFs), mode shapes and modal parameters from structural vibration to detect damage were measured, set on linear averaging mode, with a maximum frequency of analysis of 3.2 kHz....

متن کامل

A case study for application of fuzzy inference and data mining in structural health monitoring

In this study, a system for monitoring the structural health of bridge deck and predicting various possible damages to this section was designed based on measuring the temperature and humidity with the use of wireless sensor networks, and then it was implemented and investigated. A scaled model of a conventional medium sized bridge (length of 50 meters, height of 10 meters, and with 2 piers) wa...

متن کامل