Distal locking of femoral nails: evaluation of a new radiation-independent targeting system.

نویسندگان

  • Yvan Arlettaz
  • Alexander Dominguez
  • Alain Farron
  • Matthieu Ehlinger
  • Beat K Moor
چکیده

OBJECTIVES The purpose of this study was to assess the effectiveness of a novel radiation-independent aiming device for distal locking of intramedullary nails in a human cadaver model. METHODS A new targeting system was used in 25 intact human cadaver femora for the distal locking procedure after insertion of an intramedullary nail. The number of successful screw placements and the time needed for this locking procedure were recorded. The accuracy of the aiming process was evaluated by computed tomography. RESULTS The duration of the distal locking process was 8.0 ± 1.8 minutes (mean ± SD; range, 4-11 minutes). None of the screw placements required fluoroscopic guidance. Computed tomography revealed high accuracy of the locking process. The incidence angle (α) of the locking screws through the distal locking holes of the nail was 86.8° ± 5.0° (mean ± SD; range, 80°-96°). Targeting failed in 1 static locking screw because of a material defect in the drilling sleeve. CONCLUSIONS This cadaver study indicated that an aiming arm-based targeting device is highly reliable and accurate. The promising results suggest that it will help to decrease radiation exposure compared with the traditional "free-hand technique."

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of free-hand fluoroscopic guidance and electromagnetic navigation in distal locking of femoral intramedullary nails

BACKGROUND Although the method has been used widely, one of the greatest challenges for intramedullary nailing is to position the distal locking screw. A new technology, the electromagnetic navigation system, is a radiation-free way to locate the position of the drill bit and provide 3-dimensional real-time feedback of location and orientation of the drill bit relative to the locking holes. The...

متن کامل

Distal targeting device for long Gamma nail(®). Monocentric observational study.

INTRODUCTION Intramedullary nail distal locking screws make it possible to control length and rotation but include an increased risk of radiation exposure. A distal targeting device was recently developed for long Gamma(®) nails (Stryker(®)). The aim of this practical observational study was to evaluate the reliability of this system. Our hypothesis was that the targeting device would be system...

متن کامل

X-ray-based machine vision system for distal locking of intramedullary nails.

In surgical procedures for femoral shaft fracture treatment, current techniques for locking the distal end of intramedullary nails, using two screws, rely heavily on the use of two-dimensional X-ray images to guide three-dimensional bone drilling processes. Therefore, a large number of X-ray images are required, as the surgeon uses his/her skills and experience to locate the distal hole axes on...

متن کامل

Imaging Evaluation of the Safe Region for Distal Locking Screw of Proximal Femoral Nail Anti-Rotation in Patients with Proximal Femoral Fracture

BACKGROUND Proximal femoral nail anti-rotation (PFNA) is a standard femoral intertrochanteric fracture operation. Iatrogenic vascular injury, although uncommon, is a reported complication of PFNA surgery as well as a complication of hip fracture surgery. This study aimed to compare the safety and best use of the distal locking screw in 170 mm PFNA and 240 mm PFNA devices, and to determine the s...

متن کامل

A sonography assisted technique for the removal of a femoral interlocking nail – a technical note

BACKGROUND Open methods for removal of femoral interlocking nails involve an incision (up to 10 cm) over the trochanter to find the tip of the nail. The distal locking screws are some times difficult to palpate and an incision (up to about 5 cm) is often needed for exposure. Intra-operative fluoroscopy is often used as an adjunct technique to minimize the surgical wound. However, patients and s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic trauma

دوره 26 11  شماره 

صفحات  -

تاریخ انتشار 2012