Repeatability of aberrometric measurements with a new instrument for vision analysis based on adaptive optics.
نویسندگان
چکیده
PURPOSE To evaluate intersession and intrasession repeatability of aberration data obtained with a new visual simulator based on adaptive optics, which includes a Hartmann-Shack aberrometer (Adaptive Optics Vision Analyzer; Voptica S.L., Murcia, Spain). METHODS Thirty-one healthy right eyes were included in the study. To evaluate intrasession repeatability, three consecutive measurements without repositioning the patient or realigning the eye were obtained. Intersession repeatability was evaluated in three sessions. Aberrometric data computed from the second to the fifth order for a 4-mm pupil were used. Statistical analysis included the repeated measures analysis of variance (or the Wilcoxon signed rank test), the coefficient of repeatability, the Bland-Altman method, and the intraclass correlation coefficient. RESULTS No significant differences in the intrasession and intersession repeatability analysis for any of the parameters (P > .05) were found, suggesting a consistent variability of the instrument over time. Similar coefficient of repeatability values were obtained in the three sessions. The Bland-Altman analysis confirmed differences close to zero and the variations were independent of the mean within and between sessions. The intersession intraclass correlation coefficient values were generally above 0.75, suggesting moderate to high repeatability. However, some exceptions were found in the intrasession analysis. CONCLUSIONS The findings suggest that the new instrument provides consistent and repeatable aberrometric data. It is therefore a suitable tool to perform consistent and repeatable visual simulations.
منابع مشابه
Repeatability and Reproducibility of Anterior Segment Measurements in Normal Eyes Using Dual Scheimpflug Analyzer
OBJECTIVES To assess the repeatability and reproducibility of anterior segment measurements including aberrometric measurements provided by a dual Scheimpflug analyzer (Galilei) system in normal eyes. MATERIALS AND METHODS Three repeated consecutive measurements were taken by two independent examiners. The following were evaluated: total corneal power and posterior corneal power, corneal high...
متن کاملAdaptive optics visual simulator.
PURPOSE To develop a prototype instrument that uses adaptive optics to introduce virtually any desired aberration profile in a subject's eye. At the same time, the instrument could be used to evaluate the subject's spatial vision for each controlled aberration profile. This "aberration testing station" or "visual simulator" allows us to study the relationship between specific aberrations and vi...
متن کاملSynthesis of TiO2-ZnO-ZrO2 Nanocomposites for Nonlinear Optics Applications
A sol-gel technique under ultrasonic irradiation was applied to synthesize ZrO2/TiO2/ZnOnanocomposites. X-ray diffraction analysis confirmed the successful synthesis of nanocomposites. The strain and crystalline size values of ZrO2/TiO2/ZnO nanocomposites are estimated to be 9.98×10-4 and 17.66 nm, respectively. The linear absorption coefficient of ZrO2/TiO2/ZnO nanocomposites was measure...
متن کاملImpact of scatter on double-pass image quality and contrast sensitivity measured with a single instrument.
We compared objective Double-Pass (DP) image quality data with subjective visual parameters measured within the same modified instrument for different amounts of scatter. The original DP imaging channel of a clinical instrument was maintained intact and two additional channels were included, one for visual testing and another for tear film (TF) imaging by using a retro-illumination technique. C...
متن کاملCorneal Topographic and Aberrometric Measurements Obtained with a Multidiagnostic Device in Healthy Eyes: Intrasession Repeatability
Purpose. To evaluate the intrasession repeatability of corneal curvature, eccentricity, and aberrometric measurements obtained with a multidiagnostic device in healthy eyes. Methods. This study enrolled 107 eyes of 107 patients ranging in age from 23 to 65 years. All of them underwent a complete anterior segment examination with the VX120 system (Visionix-Luneau Technologies, Chartres, France)....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of refractive surgery
دوره 31 3 شماره
صفحات -
تاریخ انتشار 2015