Epipolar Consistency Conditions for Motion Correction in Weight-Bearing Imaging
نویسندگان
چکیده
Recent C-arm CT systems allow for the examination of a patient’s knees under weight-bearing conditions. The standing patient tends to show involuntary motion, which introduces motion artifacts in the reconstruction. The state-of-the-art motion correction approach uses fiducial markers placed on the patients’ skin to estimate rigid leg motion. Marker placement is tedious, time consuming and associated with patient discomfort. Further, motion on the skin surface does not reflect the internal bone motion. We propose a purely projection based motion estimation method using consistency conditions of X-ray projections. The epipolar consistency between all pairs of projections is optimized over various motion parameters. We validate our approach by simulating motion from a tracking system in forward projections of clinical data. We visually and numerically assess reconstruction image quality and show an improvement in Structural Similarity from 0.912 for the uncorrected case to 0.943 using the proposed method with a 3D translational motion model. Initial experiments showed promising results encouraging further investigation of practical applicability.
منابع مشابه
Fourier Consistency-Based Motion Estimation in Rotational Angiography
Rotational coronary angiography allows for volumetric imaging but requires cardiac and respiratory motion management to achieve meaningful reconstructions. Novel respiratory motion compensation algorithms based on data consistency conditions are applied directly in projection domain and, therefore, overcome the need for uncompensated reconstructions. Earlier, we combined single-frame background...
متن کاملRedundancies in X-ray images due to the epipolar geometry for transmission imaging
In Computer Vision, the term epipolar geometry describes the intrinsic geometry between two pinhole cameras. While the same model applies to X-ray source and detector, the imaging process itself is very different from visible light. This paper illustrates the epipolar geometry for transmission imaging and makes the connection to Grangeat’s theorem, establishing constraints on redundant projecti...
متن کاملEpipolar Consistency in Fluoroscopy for Image-Based Tracking
Geometry and physics of absorption imaging impose certain constraints on X-ray projections. Recently, the Epipolar Consistency Conditions (ECC) have been introduced and applied to motion correction in flat-detector computed tomography (CT). They are based on redundant information in transmission images along epipolar lines. Unlike other consistency conditions for CT scans, they act directly on ...
متن کاملاصلاح حرکت در تصویربرداری اسپکت میوکارد با استفاده از مدلسازی منحنی چند جمله ای
Background and purpose: Patient motion during myocardial perfusion SPECT can produce artifacts in reconstructed images which might affect clinical diagnosis. This paper attempts to present a new approach for the detection and correction of cardiac motion utilizing the data obtained during the imaging process. Materials and methods: Our method quantifies motion through polynomial curves modelin...
متن کاملAdvanced Motion Correction Methods in PET
With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2017