Intraocular Telescopic System Design: Optical and Visual Simulation in a Human Eye Model

نویسندگان

  • Georgios Zoulinakis
  • Teresa Ferrer-Blasco
چکیده

Purpose. To design an intraocular telescopic system (ITS) for magnifying retinal image and to simulate its optical and visual performance after implantation in a human eye model. Methods. Design and simulation were carried out with a ray-tracing and optical design software. Two different ITS were designed, and their visual performance was simulated using the Liou-Brennan eye model. The difference between the ITS was their lenses' placement in the eye model and their powers. Ray tracing in both centered and decentered situations was carried out for both ITS while visual Strehl ratio (VSOTF) was computed using custom-made MATLAB code. Results. The results show that between 0.4 and 0.8 mm of decentration, the VSOTF does not change much either for far or near target distances. The image projection for these decentrations is in the parafoveal zone, and the quality of the image projected is quite similar. Conclusion. Both systems display similar quality while they differ in size; therefore, the choice between them would need to take into account specific parameters from the patient's eye. Quality does not change too much between 0.4 and 0.8 mm of decentration for either system which gives flexibility to the clinician to adjust decentration to avoid areas of retinal damage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

کاربرد لنزهای داخل چشمی در جراحی کاتاراکت و عوامل تأثیرگذار بر دید بیمار

Introduction: With the growing and rapid development of refractive surgery, researches focus increasingly on improvement of visual quality after cataract surgery. Intraocular lenses (IOLs) were a successful effort in the field of cataract surgery. Despite significant advances in cataract surgery, several complications related to surgical technique and IOL design after surgery can cause vision c...

متن کامل

The lterative Nature of the Engineering Design Process: a Telescopic Revision Model (RESEARCH NOTE)

The satisfying of human needs through designing technical objects requires the compromisation and settling of various conflicting criteria at different stages of the engineering design process. The need for back and forth adjustment of design specifications, concept finding, and design embodiment can be considered to be carried out in a telescopic review fashion. The present study is concerned ...

متن کامل

Injectable intraocular telescope: Pilot study.

PURPOSE To assess the feasibility of a new injectable telescopic intraocular lens (IOL). SETTING London Eye Hospital, London, United Kingdom. DESIGN Prospective interventional pilot study. METHOD Eyes with bilateral, intermediate, or advanced dry age-related macular degeneration (AMD); preoperative decimal corrected distance visual acuity (CDVA) of 0.25 or less; and improvement with extra...

متن کامل

Study of Optical Models Regarding the Human Eye

Introduction: Until now, many models have been presented for optical study of the human eye. In recent years, surgery on the anterior section of the eye (such as cataract and photo-refractive surgery) has increased, so a study on the optics of the eye and evaluation of vision quality has become more important. Material and Methods: In this article, some of these models are considered. They incl...

متن کامل

Monte Carlo simulation of two 106Ru eye plaques in a new mathematical human eye model

  BEBIG Ruthenium-106 ophthalmic plaques have been used for treatment of uveal melanoma, retinoblastoma, melanoma of the iris and other special applications for many years. The plaques consist of a thin film of 106Ru, a beta emitter, encapsulated in pure silver. The present work proposes a new mathematical eye model for ophthalmic brachytherapy dosimetry. This new mod...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2017  شماره 

صفحات  -

تاریخ انتشار 2017