Estimation of serum gentamicin by quenching fluoroimmunoassay.

نویسندگان

  • E J Shaw
  • R A Watson
  • J Landon
  • D S Smith
چکیده

A new type of non-isotopic immunoassay, applied to the determination of serum gentamicin, is reported. The method is based on partial quenching of fluorescence observed when fluorescein-labelled gentamicin is bound by anti-gentamicin serum. The fluorescence intensity of the labelled gentamicin in an unseparated immunoassay incubation mixture therefore serves to indicate the extent of binding, which is related to the amount of competing unlabelled gentamicin present. Precision and accuracy are shown to be similar to those of the best existing methods for gentamicin, while the new assay is more rapid and technically simpler, and avoids the use of expensive radio-chemicals with their attendant health hazard. Assays of patient samples correlate with established bioassay and polarisation fluoroimmunoassay methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Continuous-flow fluoroimmunoassay of serum gentamicin, with automatic sample blank correction.

We describe the continuous-flow automation of a quenching fluoroimmunoassay for determination of the antibiotic gentamicin in serum. In the flow system, sample is mixed with fluorescein-labeled gentamicin, followed by antiserum, and after a short incubation the fluorescence is measured. The intrinsic blank signal of each sample is corrected for during its single passage through the system by pu...

متن کامل

Homogeneous, micelle quenching fluoroimmunoassay for detecting amphetamines in urine.

We developed a homogeneous fluoroimmunoassay for detecting amphetamines in urine. Only fluorescence intensity need be measured because the emission of non-protein-bound fluorescein-labeled amphetamine is preferentially quenched by detergent micelles. In a previous reported prototype assay system for measuring gentamicin in serum we used fluorescein and dodecyl sulfate (Anal Chem 1985; 57:1928-3...

متن کامل

Homogeneous time-resolved fluoroimmunoassay of thyroxin in serum.

We describe a rapid, simple nonseparation fluoroimmunoassay for determination of thyroxin in serum. The assay is based on the labeling of thyroxin directly with a fluorescent europium chelate, the fluorescence of which is quenched on binding to an antithyroxin antibody. With the assay buffer we used, maximum quenching is 90%. The rapid achievement of equilibrium in the assay solution, regardles...

متن کامل

Distance-independent quenching of quantum dots by nanoscale-graphene in self-assembled sandwich immunoassay.

A promising one-step homogeneous fluoroimmunoassay based on nanoscale-graphene sheets as powerful fluorescence acceptors and CdTe quantum dots as vigorous donors was designed to detect trace biomarker protein with distance-independent quenching efficiency, which significantly broke the distance limit (100 Å) in traditional fluorescent biosensors.

متن کامل

Study of the combination reaction between drugs and bovine serum albumin with methyl green as a fluorescence probe

We studied the combination between seven kinds of drugs and the bovine serum albumin (BSA) using Methyl Green (MG) as fluorescent probe. These drugs were Streptomycin sulphate, Kanamycin sulfate, Gentamicin, Amikacin, Neomycin, Thiamphenicol and Florfenicol. And after reaction of these drugs, the fluorescence intensity of BSA had no obvious change. Research has shown that in Tris-HCl (pH=7.40) ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 30 6  شماره 

صفحات  -

تاریخ انتشار 1977