The influence of ventricular fibrillation duration on defibrillation efficacy using biphasic waveforms in humans.

نویسندگان

  • S Windecker
  • R E Ideker
  • V J Plumb
  • G N Kay
  • G P Walcott
  • A E Epstein
چکیده

OBJECTIVES The purpose of this study was to prospectively investigate the influence of ventricular fibrillation (VF) durations of 5, 10 and 20 s on the defibrillation threshold (DFT) during implantable cardioverter-defibrillator (ICD) implantation. BACKGROUND Although the DFT using monophasic waveforms has been shown to increase with VF duration in humans, the effect of VF duration on defibrillation efficacy using biphasic waveforms in humans is not known. METHODS Thirty patients undergoing primary ICD implantation or pulse generator replacement were randomly assigned to have the DFT determined using biphasic shocks at two durations of VF each (5 and 10 s, 10 and 20 s or 5 and 20 s). RESULTS There was no statistically significant difference in the mean DFT comparing VF durations of 5 s (9.5+/-6.0 J) and 10 s (10.8+/-7.0 J) (p=0.4). The mean DFT significantly increased from 10.9+/-6.1 J at 10 s of VF to 12.6+/-5.6 J (p=0.03) at 20 s of VF, and from 7.0+/-3.5 J at 5 s of VF to 10.5+/-6.3 J (p=0.04) at 20 s of VF. An increase in the DFT was observed in 14 patients as VF duration increased. There were no clinical characteristics that differentiated patients with and without an increase in the DFT. CONCLUSIONS Defibrillation efficacy decreases with increasing VF duration using biphasic waveforms in humans. Ventricular fibrillation durations greater than 10 s may negatively affect the effectiveness of ICD therapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relative efficacy of monophasic and biphasic waveforms for transthoracic defibrillation after short and long durations of ventricular fibrillation.

BACKGROUND Recently, interest has arisen in using biphasic waveforms for external defibrillation. Little work has been done, however, in measuring transthoracic defibrillation efficacy after long periods of ventricular fibrillation. In protocol 1, we compared the efficacy of a quasi-sinusoidal biphasic waveform (QSBW), a truncated exponential biphasic waveform (TEBW), and a critically damped si...

متن کامل

Simultaneous Comparison of Many Triphasic Defibrillation Waveforms

Biphasic defibrillation waveforms are now accepted as being more effective at terminating ventricular fibrillation (VF) than monophasic waveforms. If two phases are better than one, this naturally leads to the hypothesis that additional phases improve efficacy. This study tests the hypothesis by adding one additional phase. We examined the efficacy of 18 different triphasic waveforms simultaneo...

متن کامل

A prospective randomized evaluation of biphasic versus monophasic waveform pulses on defibrillation efficacy in humans.

Biphasic waveforms have been suggested as a superior waveform for ventricular defibrillation. To test this premise, a prospective randomized intraoperative evaluation of defibrillation efficacy of monophasic and biphasic waveform pulses was performed in 22 survivors of out of hospital ventricular fibrillation who were undergoing cardiac surgery for implantation of an automatic defibrillator. Th...

متن کامل

Electrode system influence on biphasic waveform defibrillation efficacy in humans.

BACKGROUND Several clinical studies have demonstrated a general superiority of biphasic waveform defibrillation compared with monophasic waveform defibrillation using epicardial lead systems. To test the breadth of utility of biphasic waveforms in humans, a prospective, randomized evaluation of defibrillation efficacy of monophasic and single capacitor biphasic waveform pulses was performed for...

متن کامل

Effects of polarity for monophasic and biphasic shocks on defibrillation efficacy with an endocardial system.

Electrode polarity has been reported to be one of the factors that affect defibrillation efficacy. We studied the influence of polarity on defibrillation efficacy when monophasic and biphasic waveforms were used with an endocardial lead system. In six anesthetized pigs, defibrillation catheters were placed in the right ventricular (RV) apex and at the junction of the superior vena cava (SVC) an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 33 1  شماره 

صفحات  -

تاریخ انتشار 1999