Three-dimensional measurement of intervertebral kinematics in vitro using optical motion analysis.
نویسندگان
چکیده
Measurement of the stiffness of spinal motion segments is widely used for evaluating the stability of spinal implant constructs. A three-dimensional motion analysis technique has been developed that allows accurate measurement of the relative movement of the vertebral bodies about a well-defined anatomical axis system. The position of marker clusters on each vertebra is tracked using digital infrared cameras (Qualisys AB, Gothenburg). Landmarks are identified using a marked pointer, and an anatomical coordinate system is defined for each vertebra. The transformation relating the upper and lower vertebrae is calculated, using the joint coordinate system approach of Grood and Suntay to find the rotations and translations in each anatomical plane. The stiffness of vertebrectomy constructs was investigated using a Synex vertebral body replacement and an anterior rod with one or two screws in each vertebral body, with or without damage to the posterior longitudinal ligament (PLL). A moment of 2 N m was applied about each anatomical axis, and the range of motion about each axis was calculated. The range of motion in flexion-extension and lateral bending was significantly greater with only one screw. When the PLL was cut, there was no significant increase in the range of motion.
منابع مشابه
The effect of non-stability surface of support leg on the instep kicking kinematics in soccer players
Objective: The aim of this study was to investigate the effect of non- stability surface of support leg on the instep kicking kinematics in soccer players. Materials and Methods: 30 male soccer players participated in this study. After the measurement of static and dynamic balance tests by the Biodex System, 20 players were selected who were at a desired level of the balance. Data were recorded...
متن کاملComparisons of bracing and patellar taping on knee three-dimensional kinematics of women with patellofemoral pain syndrome in stance phase of running
Introduction: Patellofemoral pain syndrome (PFPS) is one of the most common knee injuries that accounted for between 25-40% of all knee problems presenting to sports medicine centers. Two treatment methods of bracing and taping are recommended in these patients that their effectiveness are unclear. The aim of this study was to evaluate the efficacy of the two treatment methods on knee three-dim...
متن کاملCervical spine intervertebral kinematics with respect to the head are different during flexion and extension motions.
Previous dynamic imaging studies of the cervical spine have focused entirely on intervertebral kinematics while neglecting to investigate the relationship between head motion and intervertebral motion. Specifically, it is unknown if the relationship between head and intervertebral kinematics is affected by movement direction. We tested the hypothesis that there would be no difference in sagitta...
متن کاملUse of three-dimensional ultrasonography of the eye and measurement of optical long axis in dog
This study was conducted to determine the use of three-dimensional ultrasonography (3DU) in ocular imaging of the dog and measuring of its optical axis. 12 healthy mixed-breed dogs including 6 males and 6 females were studied. 3DU of the eyes were done using a 5–12 MHz linear trapezoid transducer. 3DU of the eyes were evaluated and the normal optical long axis through a line between the cornea ...
متن کاملThe Effects of Increasing Running Speed on Three-Dimensional Peak Angle of the Lower Limb Joints in Stance Phase
Objective: Attention can be paid to the biomechanical characteristics of running since the speed of running varies. The aim of the present study was to investigate the effects of increasing running speed on the three-dimensional kinematics of the lower limb’ joints in the stance phase. Methods: The research was quasi-experimental. 27 volunteer subjects ran on a treadmill and the kinematic and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine
دوره 219 6 شماره
صفحات -
تاریخ انتشار 2005