Threshold doses and prediction of visually apparent liver dysfunction after stereotactic body radiation therapy in cirrhotic and normal livers using magnetic resonance imaging
نویسندگان
چکیده
The purpose of the present study was to investigate the threshold dose for focal liver damage after stereotactic body radiation therapy (SBRT) in cirrhotic and normal livers using magnetic resonance imaging (MRI). A total of 64 patients who underwent SBRT for liver tumors, including 54 cirrhotic patients with hepatocellular carcinoma (HCC) and 10 non-cirrhotic patients with liver metastases, were analyzed. MRI was performed 3-6 months after SBRT, using gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid-enhanced T1-weighted sequences. All MRI datasets were merged with 3D dosimetry data. All dose distributions were corrected to the biologically effective dose using the linear-quadratic model with an assumed α/β ratio of 2 Gy. The development of liver dysfunction was validly correlated with isodose distribution. The median biologically effective dose (BED2) that provoked liver dysfunction was 57.3 (30.0-227.9) and 114.0 (70.4-244.9) Gy in cirrhotic and normal livers, respectively (P = 0.0002). The BED2 associated with a >5% risk of liver dysfunction was 38.5 in cirrhotic livers and 70.4 Gy in normal livers. The threshold BED2 for liver dysfunction was not significantly different between Child-Pugh A and B patients (P = 0.0719). Moreover, the fractionation schedule was not significantly correlated with threshold BED2 for liver dysfunction in the cirrhotic liver (P = 0.1019). In the cirrhotic liver, fractionation regimen and Child-Pugh classification did not significantly influence the threshold BED2 for focal liver damage after SBRT. We suggest that the threshold BED2 for liver dysfunction after SBRT is 40 and 70 Gy in the cirrhotic and normal liver, respectively.
منابع مشابه
Radiomics modelling of IMRT induced acute rectal toxicity using clinical and magnetic resonance imaging features
Introduction: Rectal toxicity is a dose limiting issue in prostate cancer radiotherapy. Prediction of these effects may be used to tailor the therapy. The purpose of this work was to develop predictive radiomic models based on clinical, dosimetric and radiomic features extracted from rectal wall magnetic resonance image (MRI). Materials and Methods: This st...
متن کاملCardiac and Hepatic T2*-Weighted Magnetic Resonance Imaging
Abstract Background Iron overload is the main transfusion related side effects in patients with transfusion dependent hemoglobinopathies. Severe iron deposition in tissues leads to organ dysfunction. Many organs can be affected such as heart, liver, and endocrine organs. Cardiac failure and liver fibrosis are the consequent of Iron overload in transfusion dependent hemoglobinopathy. Magne...
متن کاملPET and MRI-guided focused ultrasound surgery for hypoxic-tissue ablation combined with radiotherapy in solid tumors
Background: The rationale was to develop an ablation approach to destroy regions of tumor resistant to radiation and thus reduce the time required for whole tumor ablation, while improving overall tumor control after radiotherapy. Materials and Methods: The system is composed of a micro positron emission tomography (mPET), 7T magnetic resonance imaging (MRI), and a customized MRI-compatible foc...
متن کاملDesign and Fabrication of a Four-Dimensional Respiratory Phantom for Studying Tumor Movement in Radiotherapy with Magnetic Resonance Imaging
Introduction: In radiation therapy, determining the location of the tumor accurately during irradiation is one of the most important requirements. However, lung tumors are not fixed in a single location and move during irradiation due to respiratory motion. Due to limitations in assessing such movements, using a lung phantom can be useful and operational for their fast, easy an...
متن کاملPseudo-CT Generation from Magnetic Resonance Imaging by fuzzy look up table algorithm
Introduction: Despite growing interest in the use of magnetic resonance imaging (MRI) in the external radiotherapy design process (RT), Computer Tomography (CT) remains a gold standard and is regarded as a basic imaging modality in radiotherapy. MRI shows the high contrast in soft tissues without any radiation exposure to patients. As a result, MRI is used in functional tissue ...
متن کامل