Intrinsic positive end-expiratory pressure during one-lung ventilation of patients with pulmonary hyperinflation. Influence of low respiratory rate with unchanged minute volume.

نویسندگان

  • L L Szegedi
  • L Barvais
  • Y Sokolow
  • J C Yernault
  • A A d'Hollander
چکیده

BACKGROUND We measured lung mechanics and gas exchange during one-lung ventilation (OLV) of patients with chronic obstructive pulmonary disease, using three respiratory rates (RR) and unchanged minute volume. METHODS We studied 15 patients about to undergo lung surgery, during anaesthesia, and placed in the lateral position. Ventilation was with constant minute volume, inspiratory flow and FIO2. For periods of 15 min, RR of 5, 10, and 15 bpm were applied in a random sequence and recordings were made of lung mechanics and an arterial blood gas sample was taken. Data were analysed with the repeated measures ANOVA and paired t-test with Bonferroni correction. RESULTS PaO2 changes were not significant. At the lowest RR, PaCO2 decreased (from 42 (SD 4) mm Hg at RR 15-41 (4) mm Hg at RR 10 and 39 (4) mm Hg at RR 5, P<0.01), and end-tidal carbon dioxide increased (from 33 (5) mm Hg at RR 15 to 35 (5) mm Hg at RR 10 and 36 (6) mm Hg at RR 5, P<0.01). Intrinsic positive end-expiratory pressure (PEEPi) was reduced even with larger tidal volumes (from 6 (4) cm H2O at RR 15-5 (4) cm H2O at RR 10, and 3 (3) cm H2O at RR 5, P<0.01), most probably caused by increased expiratory time at the lowest RR. CONCLUSION A reduction in RR reduces PEEPi and hypercapnia during OLV in anaesthetized patients with chronic obstructive lung disease.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The role of PEEP in patients with chronic obstructive pulmonary disease during assisted ventilation.

In patients with acute respiratory failure (ARF) due to acute exacerbation of chronic obstructive pulmonary disease (COPD), the intrinsic positive end-expiratory pressure (PEEPi) can significantly increase workload for ventilation. It has been suggested that, in the presence of expiratory flow limitation, application of low levels of PEEP by the ventilator can be used to reduce PEEPi and theref...

متن کامل

"Intrinsic" PEEP (PEEPi): role of expiratory muscles.

In normal subjects breathing at rest, lung volume at end-expiration corresponds with the elastic equilibrium volume, or relaxation volume (Vr), of the respiratory system. If expiratory duration is not long enough, then inspiration may begin before the system has returned to Vr, such that end-expiratory lung volume is higher than Vr. This condition is named dynamic pulmonary hyperinflation and "...

متن کامل

Intrinsic PEEP and cardiopulmonary interaction in patients with COPD and acute ventilatory failure.

Deviation of end-expiratory lung volume from the elastic equilibrium volume of the respiratory system is recognized as a cardinal feature in mechanically-ventilated patients with severe chronic obstructive pulmonary disease (COPD) and acute ventilatory failure (AVF). The presence of dynamic hyperinflation implies that alveolar pressure remains positive throughout expiration. At the end of the e...

متن کامل

Measurement of air trapping, intrinsic positive end-expiratory pressure, and dynamic hyperinflation in mechanically ventilated patients.

Severe airflow obstruction is a common cause of acute respiratory failure. Dynamic hyperinflation affects tidal ventilation, increases airways resistance, and causes intrinsic positive end-expiratory pressure (auto-PEEP). Most patients with asthma and chronic obstructive pulmonary disease have dynamic hyperinflation and auto-PEEP during mechanical ventilation, which can cause hemodynamic compro...

متن کامل

Expiratory automatic endotracheal tube compensation reduces dynamic hyperinflation in a physical lung model

INTRODUCTION The effect of expiratory endotracheal tube (ETT) resistance on dynamic lung inflation is unknown. We hypothesized that ETT resistance causes dynamic lung hyperinflation by impeding lung emptying. We further hypothesized that compensation for expiratory ETT resistance by automatic tube compensation (ATC) attenuates dynamic lung hyperinflation. METHODS A ventilator equipped with th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 88 1  شماره 

صفحات  -

تاریخ انتشار 2002